Specifications
  • Description: The EquiFount models 1100 and 1200 are designed for small numbers of livestock and are intended to be bolted on a wall in a corner. A pressurized water source is required, and an electrically heated model is available (#1100).
  • Weights & Dimensions: Both models have dimensions of 16" x 16" x 14" (40.64 x 40.64 x 35.56 cm). The non-heated and heated Model 1100 weighs 16 pounds, while the Model 1200 weighs 17 pounds.
  • Materials Necessary for Installation: Requires 1/2" x 3" galvanized lags or bolts and #834-5 insulated tube.
Materials and Products
  • Materials: Made from polyethylene.
  • Valve: Features a Miraco plastic plunger style valve.
Installation Procedures
  • Warm Climate Installation: Use 1/2" x 3" galvanized lags or bolts. Water lines should be buried below the frost line, and overhead lines need to be wrapped with heat tape.
  • Cold Climate Installation: The heat pad does not contact water, ensuring safety for animals. The water line should enter through an insulated tube (#834-5) from Miraco, which has an access hole for shut-off. Partially bury the tube below floor level to keep the water line frost-free.
Additional Notes
  • Water level adjustment and easy hook-up with a 1/2” thread are available.
  • When installing heat cable above, do not wrap it.
See more

Catalog excerpts

EquiFont Waterers-1

INSTALLATION INSTRUCTIONS AND SPECIFICATIONS FOR MODEL 1100 & 1200 READ CAREFULLY MIRACO A DIVISION OF AHRENS AGRICULTURAL INDUSTRIES, INC. BOX 686 GRINNELL, IOWA 50112 PHONE 641-236-5822 TOLL FREE 1-800-541-7866 FAX 1-641-236-3341 www.Miraco.co

 Open the catalog to page 1
EquiFont Waterers-2

PART 1 - GENERAL A. DESCRIPTION: 1. EquiFount is designed for small numbers of livestock to be bolted on a wall in the corner. A pressurized water source is required. Electrically heated model available #1100. B. WEIGHTS & DIMENSIONS: Model # 1100 1100 1200 1200 C. Description Non-heated Heated Wallmount Electric Wallmount MATERIAL NECESSARY FOR INSTALLATION: 1. 1/2" x 3" galvanized lags or bolts. PART II - MATERIALS, PRODUCTS A. VALVE: 1. Miraco plastic plunger style valve. OVERHEAD WATER SUPPLY STALL WALL WATER - ELECT. ENTRY VALVE COMPARTMENT 1/2" WATER LINE COLD CLIMATE INSTALL ELECTRIC SUPPLY...

 Open the catalog to page 2
EquiFont Waterers-3

Warm Climate Use Water line from above should be protected with the pipe sleeve or wood. Use 1/2" x 3" lags or bolts (galvanized). Lags are easiest if there is nothing on the other side of the studs, otherwise use galvanized bolts. Put nuts on the inside. Distance from the floor at the owners discretion. Cold Climate Use Water lines should be buried below frost line, overhead lines need to be wrapped with heat tape. Heat pad never comes in contact with water. Extremely safe for the animal. Molded bottom fits together air tight. Water line from below entering through an insulated tube #834-5 from...

 Open the catalog to page 3
EquiFont Waterers-4

Water Level Adjustment Photo From Underside Of Fount Easy Hook Up 1/2” thread When installing heat cable above do not wrap. Water Filter