Series 47.009.302
2Pages

{{requestButtons}}

Catalog excerpts

Series 47.009.302 - 1

Product Information A. u. K. Müller Solenoid valves Control valves Special valves and systems A. u. K. Müller GmbH & Co. KG Dresdener Str. 162 D-40595 Düsseldorf/Germany e-mail: info@akmueller.de Internet: www.akmueller.de R Description Direct acting 2/2 way solenoid valve with orifice size DN 9 for control of neutral gases and liquids. The plunger of the magnetic system is protected by spatial separation from the medium. In particular, the low dead space is a further advantage of the lever valves. Tank or boiler draining Medical engineering Laboratory / analysis equipment Industrial applications Direct acting Medium separated Minimal dead areas in valve body Long term performance capability No minimal pressure required Suitable for hot water appliances (98 °C) Easy to assemble and service Low power consumption Any fitting position High operating safety through the use of high quality materials and 100% final testing of the products Valves of this design are single chamber valves with threaded connections. The coil system can be customised for common voltage and frequency ranges on request. Typical Performance Curve under laboratory conditions The electrical operational safety is guaranteed by the electrical insulation coordination, which corresponds to the VDE 110 regulations. The manufacturing process includes a 100% electrical safety test in accordance with the VDE 0631 Part 1000 regulations. Ideally suited for dosing applications. The good thermal separation between the fluid path and the solenoid coil also allows the use of temperature sensitive media, such as in the medical technology or analytics. Due to the use of high quality materials, the valve is applicable for high ambient temperatures and medium temperatures up to 98 °C. © copyright A.u.K. Müller, subject to changes with

Open the catalog to page 1
Series 47.009.302 - 2

Product Information 2/2-way Lever Valve, DN 9   Technical Data Type Lever Solenoid Valve 2/2-way single chamber straight valve, direct acting, media separated Fitting position Any, preferably with coil upwardly Cold and heated water and physically and chemically similar media Coil type Nominal voltages see options other voltages on request Voltage tolerance ±10 % DC +10 % / -5% AC Duty cycle Protection Type Coil connections plug socket according to EN 175301‑803 (IP65) Insulation class Valve body Plunger guide stainless steel stainless steel Coil coating Filter (inlet) stainless steel (on...

Open the catalog to page 2

All Muller GmbH catalogs and technical brochures

  1. Series CF-17

    16 Pages

  2. Series CF-13

    6 Pages