Technical Specifications:
The document provides detailed specifications for three boiler models: CS5-CT300, CS5-CT400, and CS5-CT500. Key dimensions are listed in millimeters, including parameters such as A, C, D, E, F, G, H, N1, R32, Q23, T14, T24, T34, and ØZ. The boilers have varying weights, with the CS5-CT300 weighing 3130 kg, CS5-CT400 at 3530 kg, and CS5-CT500 at 3930 kg.

Performance and Operating Conditions:
The boilers operate with a maximum hydraulic test pressure of 4.5 bar and a maximum operating pressure of 3 bar. The nominal thermal efficiency is declared at 92% for all models. The nominal output power is 294 kW for CS5-CT300, 399 kW for CS5-CT400, and 491 kW for CS5-CT500. The maximum operating temperature is 90°C, and the minimum temperature for pump activation is 50°C.

Fuel and Consumption:
The boilers are designed to use wood pellets as fuel, in accordance with the EN 303-5:2012 standard. The maximum fuel consumption rates are 68.1 kg/h for CS5-CT300, 91.9 kg/h for CS5-CT400, and 113.4 kg/h for CS5-CT500. The hopper capacity is 600 kg, with autonomy ranging from 5.3 to 8.8 hours depending on the model.

Environmental and Safety Standards:
The boilers comply with Class 5 of the EN 303-5:2012 standard. Emissions at nominal heat output include dust levels of approximately 18.9 mg/Nm3 and CO emissions ranging from 0.077 to 0.132 g/Nm3 at 13% O2. The average smoke temperature at nominal heat output is 175°C with a ±20% variance.

Hydraulic and Electrical Connections:
The document specifies hydraulic connections, including inlet and outlet water sockets, and mentions a flue draught depression of -20 Pa. The boilers require a voltage of 380 V (50 Hz) for operation.

Maintenance and Modifications:
The document notes the minimum space required for maintenance activities, such as auger extraction. Pasqualicchio reserves the right to make technical, dimensional, and aesthetic modifications to improve products without prior notice.
See more

Catalog excerpts

CS5 CT 300-500-1

Dati tecnici / Technical features Attacchi idraulici / Hydraulic connection 1 Spazio minimo per I'estrazione della coclea in caso di manutenzione Minimum space for pulling out the auger in case of maintenance 2 Quote di posizione manicotto di ritorno Inlet water socket - location/dimension 3 Quote di posizione manicotto di mandata Outlet water socket - location/dimension Il consumo orario alla max potenza fa riferimento ad un combustibile avente potere calorifico pari a 17 MJ (4,72 kWh/kg) come da tabella 7 della norma EN303-5:2012 per combustibile di prova tipo "C". La Pasqualicchio si riserva di apportare modifiche tecniche, dimensionali ed estetiche ai suoi prodotti al fine di migliorarli, senza preavviso. Cio non costituisce diritto di recesso per il committente. The consumption per hour in max power refers to a fuel with a calorific value of 17 MJ (4.72 kWh/kg) as per table 7 from the EN303-5:2012 standard - test type "C "fuel. Pasqualicchio reserves the right to make technical, dimensional and aesthetic modifications to its products in order to improve them without prior notice. This does not grant a right of withdrawal for the customer

 Open the catalog to page 1

All Pasqualicchi srl catalogs and technical brochures

  1. CS5 CT 80-99

    1  Page

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.