CS5 CT 80-99

CS5 CT 80-99

Product catalog summary
Technical Specifications:
The document provides detailed measurements for two boiler models, CS5-CT80 and CS5-CT99, including dimensions such as A, B, C, D, E, F, G, H, I, L, and N1 in millimeters. It also specifies the hydraulic connections and nominal output.

Performance and Efficiency:
The CS5-80 model has a nominal thermal power of 80.12 kW with a declared thermal efficiency of 92%, while the CS5-99 model has a nominal thermal power of 99.69 kW with an efficiency of 91%. Both models comply with CLASS 5 EN 303-5-2012 standards.

Operating Conditions:
The maximum operating pressure is 4.5 bar, with a maximum operating temperature of 90°C. The boilers operate on wood pellets as per EN 303-5:2012 standards.

Fuel Consumption and Capacity:
The maximum fuel consumption is specified, with the CS5-80 consuming 7.0 kg/h and the CS5-99 consuming 5.6 kg/h. The hopper capacity is 18.4 kg for CS5-80 and 23.2 kg for CS5-99.

Environmental and Safety Features:
The document outlines emissions at nominal heat output, including dust and CO levels at 13% O2. It also details the flue draught depression and the range of the thermal relief valve.

Additional Information:
The document notes that Pasqualicchio reserves the right to make modifications to improve products without prior notice, and this does not grant a right of withdrawal for the customer.
See more

Catalog excerpts

CS5 CT 80-99-1

Dati tecnici / Technical features Attacchi idraulici / Hydraulic connection 1 Spazio minimo per I'estrazione della coclea in caso di manutenzione Minimum space for pulling out the auger in case of maintenance 2 Quote di posizione manicotto di ritorno Inlet water socket - location/dimension 3 Quote di posizione manicotto di mandata Outlet water socket - location/dimension Il consumo orario alla max potenza fa riferimento ad un combustibile avente potere calorifico pari a 17 MJ (4,72 kWh/kg) come da tabella 7 della norma EN303-5:2012 per combustibile di prova tipo "C". La Pasqualicchio si riserva di apportare modifiche tecniche, dimensionali ed estetiche ai suoi prodotti al fine di migliorarli, senza preavviso. Cio non costituisce diritto di recesso per il committente. The consumption per hour in max power refers to a fuel with a calorific value of 17 MJ (4.72 kWh/kg) as per table 7 from the EN303-5:2012 standard - test type "C "fuel. Pasqualicchio reserves the right to make technical, dimensional and aesthetic modifications to its products in order to improve them without prior notice. This does not grant a right of withdrawal for the customer

 Open the catalog to page 1

All Pasqualicchi srl catalogs and technical brochures

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.