Troubleshooting Guide for Air Power Drafter Indicator and EID Reader
1. Power and Connectivity Checks:
  • Ensure air supply and pressure regulator are functioning.
  • If the power status is not lit, inspect battery clips, wires, solenoid loom, mains supply, battery voltage, and inline fuse.
  • If the remote's LED is not lit, replace the batteries.
  • For scales status issues, ensure the indicator is switched on and the scales connect plug is synced.
  • If the inlet gate is flashing, verify that the entry gate is closed.
  • If the hold status is lit, press the draft button and check drafting ranges and limits.
  • For remote status issues, sync the radio remote.
  • If scales are flashing, enter a draft range and verify drafting range and limits.
  • If no EID is showing, try another eartag and sync the EID connect plug.
  • Check battery voltage if no lights are on the EID reader.
2. Operational Notes:
  • Test each gate operation with the remote in manual mode.
  • An empty crate cancels the draft/weigh cycle; accidental leaning will not record false weight or operate gates.
  • To pair the radio remote with the PAD6 control box, press the setup button twice, then press buttons 2 & 3 on the remote within 10 seconds.
  • To pair scales, press the setup button twice on the PAD6, then press the connect button on the scale connect plug.
  • If two sheep enter and the back gate shuts, hold the hold button to open the rear gate, back one sheep out, then press the auto button to reset to automatic drafting.
3. Drafting Modes:
  • Auto Drafting: Click button to control inlet gate 1.
  • Standard Drafting: Involves opening the inlet gate, recording the animal, and opening the exit gate.
  • Bypass Drafting: Press and hold the arrow button to control exit gates.
  • Hold then Override: Involves holding the animal, weighing, and then overriding the draft.
4. Additional Notes:
  • To cancel a drafting cycle, click the same button again to open the inlet gate.
  • To bypass an animal already in the crate, click any button, then press and hold the arrow button for the desired exit direction.
  • The drafter will not release an animal while the inlet gate is open.
  • The hold button can be pressed at any time before the animal is weighed to enter hold then draft or hold then override modes.
See more

Catalog excerpts

PAD6 QUICK REFERENCE-1

Status Lights Power Supply Tru-Test Indicator c/w Connect Plug PRATTLEY AUTO Notes • Operation of each gate can be tested with the Remote when the the PAD6 control box is in MANUAL mode. • An empty crate (zero weight) cancels the draft/weigh cycle. Accidently leaning on the crate will not record a false weight or operate the drafting gates. When testing; Open Inlet, apply weight, close inlet. • To pair the Radio Remote with the PAD6 control box, press the Setup button on the PAD6 twice, then press both buttons 2 & 3 on the Radio Remote (within 10 seconds), status REMOTE will light up. To pair the Scales to the PAD6 control box, press the setup button on the PAD6 twice then press the connect button on the Scale Connect Plug, status SCALES will light up. • If two sheep enter and the back gate then shuts, hold the HOLD button down and the rear gate will open, back one sheep out, then press AUTO button and drafter is reset to automatic drafting

 Open the catalog to page 1
PAD6 QUICK REFERENCE-2

AUTO Drafting Click button to control inlet gate 1 PRATTLEY REMOTE puts STANDARD DRAFTING HOLD then DRAFT click DRAFT button inlet gate opens empty crate click any button empty crate draft range determined inlet gate closes click HOLD button inlet gate opens animal recorded exit gate opens click DRAFT button animal weighed and held inlet gate closes animal recorded exit gate opens Hold lit while animal is held Inlet flashes if gate is blocked BYPASS Drafting Press and hold arrow button to control exit gates BYPASS MANY NOTES 1. CANCEL a drafting cycle  Click the same button again to open the...

 Open the catalog to page 2

All Prattley catalogs and technical brochures

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.