GA_ri-scope_L_RevD

Product catalog summary
Important Information Before Initial Use
This section stresses the necessity of thoroughly reading the manual before using Riester diagnostic instruments. These instruments comply with the 93/42/EEC directive for medical devices and are intended for use by trained professionals only.
Battery Handles and Initial Use
Details on Riester battery handles, including specifications for different voltage requirements and compatible batteries, are provided. Instructions for battery insertion, removal, and safety warnings regarding disposal are included.
ri-scope® L Otoscopes
Instructions for using Riester otoscopes for ear canal examination, including attaching ear funnels, using a swivel lens, and conducting pneumatic tests, are outlined.
ri-scope® L Ophthalmoscopes
Guidance on using ophthalmoscopes for eye examinations, including lens adjustments and illumination settings, is provided.
Retinoscopes and Dermatoscopes
Instructions for using retinoscopes and dermatoscopes for diagnosing eye and skin conditions are included.
Additional Instruments
Usage of other diagnostic tools such as nasal speculums, laryngeal mirrors, and operation otoscopes is covered.
Replacing the Lamp
Guidelines for replacing lamps in diagnostic instruments are provided to ensure optimal performance.
Care Instructions
Maintenance and cleaning instructions are outlined to ensure the longevity and proper functioning of the instruments.
Spare Parts and Accessories
A list of available spare parts and accessories is included, with instructions on how to order them.
Maintenance and Notices
Regular maintenance procedures and important notices regarding the use and handling of the instruments are described.
EMC Requirements
Information on electromagnetic compatibility requirements is provided to ensure the instruments meet necessary standards.
Warranty
Details of the warranty provided with the instruments, specifying terms and conditions, are included.
Technical Specifications
Specifications for various medical instruments, including voltage, current, and lifespan, are detailed. LED versions offer longer lifespans compared to traditional models.
Ophthalmoscopes
Designed for eye examination, these devices feature correction lenses, apertures, and filters to enhance examination capabilities.
Retinoscopes
Used for determining eye refraction, these devices allow for rotation and fixation card use.
Dermatoscopes
Used for early detection of pigmented skin changes, they come with interchangeable skin attachments.
Lamp Carriers and Nasal Speculums
Used for illuminating and examining the oral cavity and nasal interior, respectively, with interchangeable heads.
Spatula Holders and Laryngoscopes
Designed for oral and throat examination, these tools require a lamp carrier for optimal lighting.
Veterinary and Human Otoscopes
Used for ear examination and minor operations, featuring a swiveling magnifying lens.
Maintenance and Care
Instructions for cleaning, disinfection, and lamp replacement are provided. Instruments should not be submerged in liquids or machine sterilized.
Environmental and Electromagnetic Compatibility
Operating and storage conditions are specified, along with precautions regarding electromagnetic interference.
Specifications and Usage
Specifications and usage guidelines for the Riester diagnostic instrument set, specifically the ri-scope® L, are outlined. The document emphasizes using Riester accessories to maintain device integrity.
Electromagnetic Compatibility
The ri-scope® L is tested for electromagnetic interference and is compliant with IEC standards.
Battery Handles and Initial Use
Details on compatible battery handles, including instructions for inserting and removing batteries, are provided.
Recommendations for Use
Users are advised to maintain specific distances between the ri-scope® L and other HF communication devices to prevent interference.
Safety Precautions
Important safety information includes observing operating instructions and using the device only with Riester-approved accessories.
Battery and Charging Instructions
Instructions for charging and handling batteries to extend service life and ensure safety are provided.
Instrument Handling
Instructions for fitting instrument heads, switching on/off, and adjusting light intensity are included.
Disinfection and Maintenance
Guidelines for cleaning and disinfecting instruments to ensure safety and maintain device value are provided.
Electromagnetic Emissions and Immunity
The ri-scope® L is designed to operate in specific electromagnetic environments, with guidelines for emissions and immunity to disturbances.
Power Supply and Battery Handling
Details on battery handles for powering instrument heads, with specific types and configurations, are provided.
Environmental Conditions
Operating and storage conditions, including temperature and humidity ranges, are specified.
Important Notices
The document emphasizes using Riester instruments and accessories exclusively for proper function and safety.
See more

Catalog excerpts

GA_ri-scope_L_RevD-1

ri-scope® ri-scope® L ri-derma® Gebrauchsanweisung eisung nstrumente Diagnostische Instrumente Instructions ruments Diagnostic Instruments Mode d’ emploi agnostiques Instruments diagnostiques ara Instrucciones para el uso iagnósticos Instrumentos diagnósticos Инструкция по эксплуатации кие Диагностические прибор

 Open the catalog to page 1
GA_ri-scope_L_RevD-2

1. Wichtige Informationen zur Beachtung vor Inbetriebnahme 06 5. Retinoskope Slit und Spot 09 1. Important information to observe prior to initial use 15 2. Battery handles and initial use 15 5. Slit and spot retinoscopes 18 11. Operation otoscope for veterinary medicine 19 12. Operation otoscope for human medicine 20 15. Spare parts and accessories 21 1. Informations importantes a lire attentivement avant la mise en service 23 2. Manches a piles et mise en service 23 5. Retinoscopes a trait et a spot 26 9. Support pour abaisse-langue 27 10. Miroir pour larynx 28 11. Otoscope chirurgical pour...

 Open the catalog to page 2
GA_ri-scope_L_RevD-3

Indice pagina 1. Importanti avvertenze da rispettare prima dell’uso 2. Manico portabatterie e messa in funzione 3. Otoscopio ri-scope®L 4. Oftalmoscopio ri-scope®L 5. Retinoscopio Slit e Spot (a linea e punto) 6. Dermatoscopio 7. Portalampadina 8. Specolo nasale 9. Porta abbassalingua 10. Laringoscopio 11. Otoscopio operatorio per lanmedicina veterinaria 12. Otoscopio operatorio per la medicina umana 13. Sostituzione della lampadina 14. Avvertenze per la cura dello strumento 15. Ricambi e accessori 16. Manutenzione 17. Avvertenze 18. Requisiti CEM Garanzia Cодержание 1. Bажные указания перед...

 Open the catalog to page 3
GA_ri-scope_L_RevD-6

1.Wichtige Informationen zur Beachtung vor Inbetriebnahme Sie haben ein hochwertiges Riester DiagnostikBesteck erworben, welches entsprechend der Richtlinie93/42/EWG für Medizinprodukte hergestellt wurde und ständigen strengsten Qualitätskontrollen unterliegt. Die hervorragende Qualität wird Ihnen zuverlässige Diagnosen garantieren. In dieser Gebrauchsanweisung werden der Gebrauch der Riester Batteriegriffe der ri-scope® bzw. ri-derma® Instrumentenköpfe und deren Zubehör beschrieben. Bitte lesen Sie die Gebrauchsanweisung vor Inbetriebnahme sorgfältig durch, und bewahren Sie sie gut auf. Sollten...

 Open the catalog to page 6
GA_ri-scope_L_RevD-7

ACHTUNG: Bei Lithium Batterien (nur bei Batteriegriffe Typ C) benötigen Sie eine Reduzierhülse (Art. Nr.: 12652) + LDO-Regler (Art. Nr.: 12653) Griff C Bei Nachrüstung: Drehen sie den Griffdeckel am unteren Teil des Handgriffes ab. Bei Lithium Batterien wird die Reduzierhülse mit dem Ende, wo der Federspannring sitzt, zuerst in die Griffhülse eingesetzt, der LDO-Regler wird in Richtung des aufgedruckten Pfeiles eingesetzt. Die Lithium Batterien werden so eingesetzt, dass die Pluspole in Richtung Griffoberteil zeigen. Drehen sie den Griffdeckel wieder fest auf den Handgriff auf. Griff AA Bei Nachrüstung:...

 Open the catalog to page 7
GA_ri-scope_L_RevD-8

2.5 Ein- und Ausschalten Batteriegriffe Typ C und AA Schalten Sie das Instrument ein, indem Sie den SchaLtring am Griffoberteil in Richtung Uhrzeigersinn antippen. Um das Instrument auszuschalten drucken Sie den Ring entgegen dem Uhrzeigersinn bis sich das Gerat ausschaltet. 2.6. rheotronic® zur Regulierung der Lichtintensitat Anhand der rheotronic® ist es moglich die Lichtintensitat an den Batteriegrif-fen Typ C und AA einzustellen. Je nach dem, wie oft Sie den SchaLtring entgegen oder in Richtung Uhrzeigersinn antippen, ist die Lichintensitat schwacher oder starker. ACHTUNG: Bei jedem Einschalten...

 Open the catalog to page 8
GA_ri-scope_L_RevD-9

Halbmond, kleine/mittlere/große Kreisblende, Fixierstern und Slit. Ophthalmoskop L3 Halbmond, kleine/mittlere/große Kreisblende, Fixierstern, Slit und Karo. Blende zur Untersuchung bei trüben Linsen Kleiner Kreis: zur Reflexminderung bei kleinen Pupillen Mittlerer Kreis: zur Reflexminderung bei kleinen Pupillen Großer Kreis: zur topographischen Feststellung von Netzhautveränderungen zur Feststellung von zentraler oder exzentrischer Fixation 4.4 Filter Über das Filterrad können zu jeder Blende folgende Filter zugeschaltet werden: Ophthalmoskop L1 Rotfreifilter Ophthalmoskop L2 Rotfreifilter, Blaufilter...

 Open the catalog to page 9
GA_ri-scope_L_RevD-10

mittl. Lebensdauer 15h mittl. Lebensdauer 15h mittl.Lebensdauer 1 0000h 6. Dermatoskop 6.1. Zweckbestimmung Das in dieser Gebrauchsanweisung beschriebene Dermatoskop ri-derma® wird zur Fruherkennung von pigmentierten Hautveranderungen (malignen Me-lanomen] hergestellt. 6.2. Inbetriebnahme und Funktion Setzen Sie den gewunschten Instrumentenkopf so auf die Aufnahme am Grif-foberteil auf, dass die beiden Aussparungen des Unterteils des Instrumen-tenkopfes auf die beiden hervorstehenden Fuhrungsnocken des Batteriegriffes aufsitzen. Drucken Sie den Instrumentenkopf leicht auf den Batteriegriff und...

 Open the catalog to page 10
GA_ri-scope_L_RevD-11

9.2. Inbetriebnahme und Funktion Setzen Sie den gewünschten Instrumentenkopf so auf die Aufnahme am Griffoberteil auf, dass die beiden Aussparungen des Unterteils des Instrumentenkopfes auf die beiden hervorstehenden Führungsnocken des Batteriegriffes aufsitzen. Drücken Sie den Instrumentenkopf leicht auf den Batteriegriff und drehen Sie den Griff in Richtung Uhrzeigersinn bis zum Anschlag. Das Abnehmen des Kopfes erfolgt durch Drehung entgegen dem Uhrzeigersinn. Führen Sie einen handelsüblichen Holz- oder Kunststoffspatel in die Öffnung unterhalb des Lichtaustrittes bis zum Anschlag ein. Nach...

 Open the catalog to page 11
GA_ri-scope_L_RevD-12

finger oder eines geeigneten Werkzeuges aus dem Instrumentenkopf. Setzen Sie die neue Lampe fest ein. Ophthalmoskope Nehmen Sie den Instrumentenkopf vom Batteriegriff ab. Die Lampe befindet sich unten im Instrumentenkopf. Entnehmen Sie die Lampe mittels Daumen und Zeigefinger oder eines geeigneten Werkzeuges dem Instrumentenkopf. Setzen Sie die neue Lampe fest ein. ACHTUNG: Der Stift der Lampe muss in die Führungsnut am Instrumentenkopf eingeführt werden. Operationsotokope Veterinär/Human Drehen Sie die Lampe aus der Fassung im Operationsotoskop und drehen Sie eine neue Lampe wieder fest ein. 14....

 Open the catalog to page 12
GA_ri-scope_L_RevD-14

Leitlinien und Herstellerklärung – Elektromagnetische Störfestigkeit Das Model ri-scope® L ist für den Betrieb in der unten angegebenen elektromagnetischen Umgebung bestimmt. Der Kunde oder der Anwender des ri-scope® L sollte sicherstellen, dass es in einer solchen Umgebung benutzt wird. StörfestigkeitsIEC 60601 Übereinstimmungs- Elektromagnetische Umgebung - Leitlinien Prüfung Prüfpegel Pegel Tragbare und mobile Funkgeräte werden in keinem geringeren Abstand zum ri-scope® L einschließlich der Leitungen als dem empfohlenen Schutzabstand verwendet, der nach der für die Sendefrequenz geeigneten...

 Open the catalog to page 14