CoMeo

CoMeo
1 / 16 PagesView full catalog

CoMeo

Product catalog summary
General Information
The document stresses the importance of complying with legal regulations, especially European directives, for installations designed for intensive livestock use. Liability is limited if the product is misused or unauthorized modifications are made.

Personnel Qualifications
Users must understand instructions and have technical knowledge of the installation. Assembly and maintenance require technically trained personnel.

Storage and Transport
Components should be stored in weather-protected areas, and transport requires a forklift operated by a qualified person.

Dismantling and Waste Disposal
Dismantling must adhere to local environmental laws. Electrical waste should be taken to official collection points.

Noise Emission
The noise level is below 70 dB(A).

Lock Out - Tag Out - Try Out (LOTOTO)
This safety procedure involves blocking energy sources, marking them, and ensuring safety before maintenance.

Use of Personal Protective Equipment
Appropriate protective gear, such as gloves and dust masks, is required.

Lighting Requirements
A minimum of 200 lux is necessary for usage, maintenance, and installation.

Electrical Equipment
Control panels require at least 70 cm of free space and must remain closed. Maintenance should be performed by authorized personnel.

Safety Signs and Symbols
Three danger levels are indicated: DANGER, WARNING, and CAUTION, each with specific safety implications.

General Safety Rules
Disconnect electricity before repairs or maintenance. Unauthorized persons should not enter the area. Regular checks and maintenance are essential for safety and functionality.

Operator’s Guide
Includes instructions for operating the system, starting procedures, and age-related guidelines for broilers.
Specifications and Procedures
The document details the operation and maintenance of the Roxell automatic pan feeding system for broilers, including adjusting feeder height and ensuring proper control pan operation. The system is designed for floor feeding from day-old chicks to broilers.

Maintenance Instructions
Regular maintenance is crucial for optimal performance, including dust-free power unit fans, checking electrical wiring, and maintaining the suspension system. Tasks are scheduled monthly, bi-annually, and annually.

Cleaning Procedures
Cleaning involves emptying tubes, removing feed residues, protecting electrical components, and using a high-pressure cleaner. Consultation with the supplier is advised when using aggressive detergents.

Troubleshooting Guide
Solutions for common issues like feeder lines not running and motor overload include checking current supply and replacing defective components.

Standards and Compliance
The document includes declarations of conformity with European directives and standards, ensuring compliance with machinery and electromagnetic compatibility requirements.

Key Recommendations
Ensure maintenance and troubleshooting are performed by qualified personnel. Regularly check and adjust system components to maintain efficiency. Follow cleaning and maintenance schedules to prolong the system's lifespan.
See more

Catalog excerpts

CoMeo-1

User Guide Original User Guide

 Open the catalog to page 1
CoMeo-2

COMEO IN LINE - USER'S GUIDE - EU TABLE OF CONTENTS GENERAL INFORMATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1. OBEY THE LEGAL REGULATIONS AND THE APPLICABLE RULES! . . . . . . . . . . . . . . . . . 6. INFORMATION ABOUT THE RESIDUAL RISKS - USED SAFETY SIGNS . . . . . . . . . . . . . . 10. THE LEVEL OF NOISE EMISSION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11. LOCK OUT TAG OUT – LOCK METHOD GENERAL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12. USE...

 Open the catalog to page 2
CoMeo-3

Disclaimer The original, authoritative version of this manual is the English version produced by ROXELL BV. Subsequent changes to any manual made by any third party have not been reviewed nor authenticated by Roxell. Such changes may include, but are not limited to, translation into languages other than English, and additions to or deletions from the original content. Roxell disclaims responsibility for any and all damages, injuries, warranty claims and/or any other claims associated with such changes, in as much as such changes result in content that is different from the authoritative Roxell-published...

 Open the catalog to page 3
CoMeo-4

– General information General information IMPORTANT: These instructions must be read, understood and all points observed by the user, the responsible and operating personnel. Obey the legal regulations and the applicable rules This concerns, among other things, the European regulations and directives transposed into national legislation and/or the laws, safety and accident prevention regulations that apply in the user's country. During assembly, operation and maintenance of the installation the legal regulations concerned and the applicable technical rules must be obeyed. The installation has...

 Open the catalog to page 4
CoMeo-5

– General information Technically trained person An expert who can assemble and maintain the installation (mechanically/electrically), and resolve malfunctions. On the basis of his/her technical training and experience, he/she has sufficient knowledge to be able to assess activities, recognize possible dangers and rectify dangerous situations. Put all parts to be assembled in a room or at a location where the not yet assembled components are protected against weather influences. Depending on the size of the parts and according to local circumstances and local legislation, the parts of the machine...

 Open the catalog to page 5
CoMeo-6

– General information LOTOTO = Lock Out - Tag Out - Try Out Before you begin: Everyone needs his own lock and tag (label), which can’t be removed by other persons. Inform all the persons who are influenced by the procedure. Localize all sources of energy (electric, hydraulic, pneumatic). Switch off. Take the relevant installation or process out of operation and lock it against reuse. You can do this by placing a padlock or other blocking mechanism (Lock Out). To mark Attach a sign, label or sticker to the padlock or blocking mechanism to reveal the nature and the expected duration of the work...

 Open the catalog to page 6
CoMeo-7

– General information Information about the residual risks - used safety signs There are three levels of danger, which you can recognize from the following signal words: • DANGER • WARNING • CAUTION The nature and source of the imminent danger and possible consequences of not obeying warnings is stated here! Symbol Meaning DANGER indicates a direct imminent danger that can result in a serious or even fatal accident if the safety measures are not respected. WARNING indicates a possible imminent danger that can result in a serious accident or damage to the product if the safety measures are not...

 Open the catalog to page 7
CoMeo-8

GENERAL SAFETY RULES Minimax/HaïKoo/Comeo Automatisch pannen voedersysteem voor vleestkuikens Automatic pan feeding system for broilers Winching systeem Liersysteem voor voer- en drinklijnen Winching system for feed- and drink lines IMPORTANT DANGER Carefully read the following instructions before USING the system 1. Before you do any repair, or maintenance works, always disconnect the electricity supply. 2. Ensure you wear personal protection equipment (gloves, dust masks). 3. The system starts automatically. Never use your hands at dangerous locations (feed intake boots, drive units, control...

 Open the catalog to page 8
CoMeo-9

OPERATOR’S GUIDE For floor feeding - from day-old chicks to broilers. AVOID FEED WASTAGE = ADJUST FEEDER HEIGHT EASY START open feed windows COMEO IN LINE - USER'S GUIDE - EU closed feed windows pans full automatic operation of control pan (FIXED/MOVABLE INTERMEDIATE) CONTROL PAN (for partial brooding) AVOID DRAUGHTS AVOID DARKNESS SUPPORT FOR HOPPER IN LINE = THE MOST USED PAN CHECK THE SUSPENSIONS OF THE 100 KG HOPPER AND THE CONTROL UNIT AFTER HEATING UP THE BUILDING. BOTH SUSPENSIONS MUST BE WELL STRETCHED.

 Open the catalog to page 9
CoMeo-10

CLEANING * The last day : run the tubes empty and let the birds empty the pans as much as possible. * Remove possible feed residues by turning the pans a couple of times 180 degrees around the tubes or by removing the pans from the 12 fin supports. * Protect electrical components against water. * Clean the whole system by means of a high- pressure cleaner (max. 100 Bar). * When using aggressive detergents or disinfectants consult your supplier. OPTION COMEO WITH CLEANING OPTION

 Open the catalog to page 10
CoMeo-11

COMEO IN LINE - USER'S GUIDE - EU ACTIONS IN GREY BACKGROUND MUST BE DONE BY A TECHNICALLY TRAINED PERSON. 1. Power unit - Make fan dust-free - Check possible damages to electrical wiring 2. Poultry intake boot with sensor - Check sensor 3. 100kg hopper (lines) - Check level switch 4. Suspension X - Check operation of (central) winch - Check operation of (central) winch. Grease after cleaning. X - Check connection of cable X - Check connection of pulleys X - Check suspension of tubes and motors X - Keep suspension cord/cable in tension 5. Poultry perch cable above the tubes/elbows - Check cable...

 Open the catalog to page 11
CoMeo-12

TROUBLE SHOOTING GUIDE Switch off the main switch first. Use personal protective equipment. DANGER ACTIONS IN GREY BACKGROUND MUST BE DONE BY A TECHNICALLY TRAINED PERSON. CORRECTIVE ACTION 1.None of the feeder No current. lines run. Defective time clock. Time clock not properly set. 2.One/more lines do Wires from motor damaged. not run. Pans are empty Motor protection switched off. Defective sensor/minimum switch control unit or 100kg hopper. Oil on auger overloads the motor. 3.Motor is often overloaded. Not enough current supply to the motors. 5.Tubes / boot wear rapidly, much noise when system...

 Open the catalog to page 12

All ROXELL bvba catalogs and technical brochures

  1. MiniMax

    2  Pages

  2. Blu’Hox

    14  Pages

  3. Dos7 TM

    14  Pages

  4. Le Roozzt

    12  Pages

  5. Swii'Flo

    44  Pages

  6. sparkcup

    28  Pages

  7. Boozzter

    20  Pages

  8. HaiKoo

    18  Pages

  9. LaiCa

    16  Pages

  10. Vitoo

    18  Pages

  11. Kixoo

    24  Pages

  12. leroozzt

    12  Pages

  13. lailineline

    16  Pages

  14. Lailine

    14  Pages

  15. Dozit

    12  Pages

  16. multiflex-

    12  Pages

  17. Dos

    12  Pages

  18. bridolay

    16  Pages

  19. Roxell Broilers

    20  Pages

  20. Roxell Pigs

    20  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.