1. Catalogs
  2. Safeguard Analytics
  3. Model SA-5100D-CH4

Model SA-5100D-CH4

Model SA-5100D-CH4

Model SA-5100D-CH4

Product catalog summary
Features – Functions - Benefits
  • Utilizes Optical NDIR sensor technology.
  • Sensitivity range of 0-5000 ppm CH4 with a minimum detectable level of 100 ppm.
  • Includes a built-in color graphic HMI and 12-month data logging capability.
  • Outputs via Modbus RTU at 9600 bps.
  • No periodic calibration required, but annual bump test and zero recommended.
  • Life expectancy exceeds 10 years.
Description

The SA-5100D-CH4 is a highly sensitive methane sensor using non-dispersive infrared (NDIR) technology for hydrocarbon absorption detection. It features a diffusion captive open path optical chamber.

Specifications
  • Electrical: Operates on 10-30 VDC, nominal 24VDC, with a power consumption of 2.5 watts.
  • Environmental: Functions in temperatures from –40°F to +158°F (-40°C to +70°C) and humidity from 15-95% non-condensing.
  • Mechanical: Constructed with electropolished 316 stainless steel, dimensions are 3.4” OD, 8.1” L (86.5mm OD, 206 mm L).
  • System: T90 response time is less than 90 seconds, with a 2-year warranty.
Area Classification

Suitable for hazardous locations: Class I; Division 1; Groups BCD and Class I Zone 1; Group IIB +H2.

Optional Components and Accessories
  • Various junction boxes, local display, alarm relay module, LoRaWAN and MODBUS transmitter modules, and a magnetic wand for calibration.
User Interface
  • Digital display with real-time readings and full script user interface.
  • System status indicators: Green for normal, Amber for level 1 warning, Red for level 2 warning, Blue for fault condition.
OpCheck Performance Diagnostics
  • Includes diagnostics for zero stability, response time, span drift, signal stability, and signal strength.
Response Factor Data

Provides response factors for various gases, with methane having a factor of 1.0.

See more

Catalog excerpts

Model SA-5100D-CH4-1

Highly Sensitive CH4 Sensors Features – Functions - Benefits • • Minimum detectable level 100 ppm Built-in color graphic HMI Embedded 12 month 1/m data logging No periodic calibration required Annual bump test and zero recommended Optical NDIR sensor technology

 Open the catalog to page 1
Model SA-5100D-CH4-2

System Detector Type Detection Method Range of Sensitivity Minimum Detectable Level Response Time Warranty Enclosure Material Non dispersive infrared (NDIR) HC absorption Diffusion captive open path optical chamber 0-5000 ppm CH4 100 ppm ± 25 ppm T90 less than 90 seconds 2 Years OpCheck Performance Diagnostics Electrical Specifications User Interface Digital Display User Interface System Status Indicators Electropolished 316 stainless steel Input Voltage Power Consumption Serial Output Optional Local Alarm Relays Real time readings and full script user Magnetic Wand- zero and span calibration...

 Open the catalog to page 2

All Safeguard Analytics catalogs and technical brochures

  1. Model SA-200

    2  Pages

  2. Model SA2

    1  Page

  3. Model SCX

    2  Pages

  4. Model SA-xES

    2  Pages

  5. Model SA-xDS

    2  Pages

  6. Model SA-1N4

    2  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.