Data Logger Overview
The Model SA-XES gas detection systems include an internal data logging function that can store real-time readings for up to 30 days with a data capture rate of one minute. It logs date-time stamped readings, calibration, and alarm events, accessible via MODBUS output.

Model SA1 Smart Sensor Modules
The system monitors various gases using different detection technologies, including catalytic pellistor for combustible gases, MPS™ for combustible gases and refrigerants, non-dispersive infrared for hydrocarbons, electrochemical sensors for toxic gases and oxygen depletion, photoionization detectors for volatile organic compounds, and metal oxide semiconductors for refrigerants. It features an embedded CPU, signal conditioning circuit, and stores gas type, measurement range, and calibration data.

Features and Benefits
The system supports 1-8 smart gas sensor modules for detecting toxics, oxygen, combustibles, and VOCs. It includes meteorological sensors for wind speed, direction, temperature, humidity, atmospheric pressure, particulate matter, rainfall, and noise. Connectivity options include wired RS-485 MODBUS RTU, wireless 915 MHz radio, and LoRa WAN wireless transceiver.

Specifications
Electrical Specifications: Input voltage is 10-30 VDC, nominal 24VDC, with an optional 110/220 VAC power supply. Power consumption is approximately 4.5 watts, varying by sensor type and number. Serial output is Modbus RTU 9600 bps, with optional local alarm relays.
Environmental Specifications: Operates in temperatures from –4°F to +122°F (-20°C to +50°C) and humidity from 15-95% non-condensing.
Mechanical Specifications: The enclosure is made of polycarbonate, with dimensions of 16” H x 14” W x 8” D (406mm H x 355mm W x 203mm D).
System Specifications: Supports 1-8 Model SA1 Smart Sensor Modules with sample draw detection via an internal smart pump. Local display indicators include green for normal operation, amber for warning level 1, red for warning level 2, and blue for fault conditions.

Model SA1 Smart Sensor Modules
The modules cover a wide range of gases, each with specific model numbers and detection ranges. Examples include combustible gases, oxygen depletion, VOCs, carbon dioxide, and various toxic gases like ammonia, chlorine, and hydrogen sulfide. For additional gas types and sensitivity ranges, refer to the Model SA1 product guide or contact the factory.
See more

Catalog excerpts

Model SA-xES-1

Air Pollution - Gas Emissions Monitor Features – Functions - Benefits • 1-8 Smart Gas Sensor Modules Toxics - Oxygen – Combustibles - VOCs Meteorological Sensors Wind speed - Wind Direction -Temperature - Humidity Atmospheric Pressure - Particulate Matter - Rainfall - Noise Serial Output - Modbus RTU 9600 bps Installation and Connectivity Options Wired RS-485 MODBUS RTU Wireless 915 MHz Radio LoRa WAN Wireless Transceiver Data Logger Model SA-XES gas detection systems feature an internal data logging function capable of storing real time readings for up to 30 days based on a data capture rate of one minute. In addition to storing date time stamped real time readings the calibration and alarm events are stored for access as needed. Logged data is stored in the system controller and accessed through the MODBUS output. Model SA1 Smart Sensor Modules • • • • • Embedded CPU and signal conditioning circuit Stored gas type and measurement range Stored zero calibration data point Stored span calibration data point Comprehensive fault diagnostics Catalytic Pellistor Combustible Gas MPS™ Combustible Gas and Refrigerants Combustible Hydrocarbons (Non-dispersive infrared) Electrochemical Toxic Gases Electrochemical Oxygen Depletion Photo Ionization Detector Volatile Organic Compounds Met

 Open the catalog to page 1
Model SA-xES-2

Model SA-XES Electrical Specifications System Detector Type Detection Method Indicators-Local Display OpCheck Performance Diagnostics User Interface Warranty Input Voltage 1-8 Model SA1 Smart Sensor Modules Sample draw via internal Smart Pump Color Graphic Digital Display Green – Normal Operation Amber – Warning Level 1 Red – Warning Level 2 Blue- Fault Condition Detected Zero Stability Response Time Span Drift Signal Stability Sensor Life Magnetic Wand 2 Years Power Consumption (varies by number and type of Smart Sensors) Serial Output Optional Local Alarm Relays Modbus RTU 9600 bps Alarm level...