Shearwell Data Livestock Systems OWNER’S GUIDE Shearwell Weigh Crate 701C Working to help the livestock farmer Power supply options 3 Contact our helpful team today 01643 841611 www.shearwell.co.uk

Open the catalog to page 1
Weigh Crate - 2

Safety Notice • 240V AC or 110V AC installation should be in accordance with current IEE wiring regulations. • User is advised to provide suitable protection for the mains supply, such as RCD. • The weight crate should be installed in a location protected from the weather. • Only use the power cables supplied with the weigh crate. • There are no operator serviceable parts inside the SDL 150 reader or the antennae. • Do not remove the cover or expose the inside of the SDL 150 reader for any reason. • Do not attempt to repair or replace any part of the reader or antennae. • Do not allow the...

Open the catalog to page 2
Weigh Crate - 3

Power supply options The power supply has ports on the underside of the box. • Mains In is for the heavy mains cable. • Reader 12V out is for the EID reader cable. • 5V out are USB ports for charging a weigh head or an X6 stock recorder • 12V out is for charging a Workabout Pro stock recorder. The SDL150 EID tag reader is supplied with three cables for different power options: • A heavy cable for connecting directly into the mains supply. • A smaller lead for connecting to the 12V port on the power supply box. • A lead for connecting to a 12V battery. A weigh head can work for many hours on...

Open the catalog to page 3
Weigh Crate - 4

Set the weigh head and the stock recorder into their mounting brackets. • Attach the two cables from the load bars to the ports on the bottom of the weigh head. • To charge the weigh head connect the power lead to the centre port and the other end to either the mains or the power supply box. Port for load bar cable Port for power lead Port for load bar cable • To charge the stock recorder connect the charging cable from the stock recorder cradle to the mains power or to a port on the power supply box. Connect the SDL 150. • Attach the black and red power cable to the bottom of the SDL 150...

Open the catalog to page 4
Weigh Crate - 5

Bluetooth connection to the SDL150 race reader • On the X6 main screen tap the Bluetooth icon. Make sure the Bluetooth is set to On. • Tap Pair new device to find the signal from the SDL150. Tap SDL 150 • Tick the box to allow access to your details and tap Pair. Return to the main screen. • Open Stock Recorder. Go to Devices • Select RF Reader. The internal reader is connected. Tap the search icon to find the SDL150. Search icon • Tap SDL150. • Tap Connect. The status bar at the top of the screen will change to green when connected. • Press ESC to exit, then pair the weigher. Contact our...

Open the catalog to page 5
Weigh Crate - 6

• On the X6 main screen tap the Bluetooth icon. Make sure the Bluetooth is set to On. • Tap Pair new device to find the signal from the weigher. • Tap ShearWeigh or EziWeigh. • Tick the box to allow access to your details and tap Pair. Return to the main screen. • Open Stock Recorder. Go to Devices Contact our helpful team today 01643 841611 www.shearwell.co.uk 1 Select Weigh Head. Tap the search icon to find the weigher. • Tap ShearWeigh or EziWeigh. • Tap Connect. The status bar at the top of the screen will change to green when connected. • Go to sheep or cattle procedures to start...

Open the catalog to page 6
Weigh Crate - 7

Weigh animals There are six weigh options for sheep and four for cattle. – Weigh Only (cattle and sheep) - Records the date, each animals’ tag number and weight. – Weaning Weight (cattle and sheep) - Use this option to record weaning weights and dates. Information will be transferred into FarmWorks on the PC and will be included in Weaning Reports and used as the starting weight for some daily weight gain reports. – Weigh and Grade (cattle and sheep) - Record the weight and fat grade. – Weigh and Condition Score (cattle & sheep) - Record weight and body condition score. – 8 Week (sheep...

Open the catalog to page 7
Weigh Crate - 8

Trouble-shooting Guide Problems with Bluetooth 1. If the X6 stock recorder was switched off, in sleep mode or was moved out of range then it will lose the Bluetooth connections. - Make sure the X6 stock recorder is powered on and in range. 2. Check that all cords and plugs are secure. If the power supply fails for even a second the Bluetooth connections will be broken. 3. If none of these resolve the problem switch everything off, disconnect the mains and take the X6 out of the cradle. - Reconnect the mains and turn everything back on again. - Reboot the X6 stock recorder (press and hold...

Open the catalog to page 8
Weigh Crate - 9

Shearwell Data Support contact Livestock Systems Working to help the livestock farmer Vn.27.06.2023 "I" UK technical support Shearwell Data Ltd Putham Farm, Wheddon Cross Minehead, Somerset, UK USA technical support Shearwell U.S.A. Support Dan Persons Kensington, Minnesota Tel: 320 760 4696 Email: dan.persons@shearwell.com www.shearwell.com Canada technical support Shearwell Canada Support Tel: 780 674 9564 Erona Farms Ltd Email: casupport@shearwell.co.uk Barrhead, Alberta www.eronafarms.ca