JADE-S2

JADE-S2

Product catalog summary
Swiss Technology Features:
  • Developed by the inventor of the Piezo method, offering a well-proven system.
  • Includes permanent feedback control and real-time power adjustments for enhanced safety and comfort.
  • Provides precise settings and power delivery for various dental treatments including scaling, periodontal, endodontic, and restorative procedures.
  • Capable of up to 32,000 linear instrument movements per second, ensuring minimal abrasion to tooth surfaces.
  • Designed for gentle and comfortable endodontic applications with increased power for restorative procedures.
  • Offers optimum instrument control and efficiency across all applications.
  • Features a powerful Swiss module with minimal operating noise and an extremely compact design.
  • Equipped with an ultraslim lightweight handpiece and a large selector for effortless and precise settings.
Ultrasonic Scaler Specifications:
  • Power input: AC 100-240V, 50/60Hz.
  • Output power: 8 Watts.
  • Frequency range: 24-32 kHz.
  • Water pressure: 1-5 bar (0.1-0.5 Mpa).
  • Weight: 1 kg.
  • Dimensions: 92*150*215 mm.
  • Irrigation: External bottle.
Portable High-frequency Dental X-ray (Model: DX10P-B):
  • Tube Voltage: 60kV, Tube Current: 1.5mA.
  • Time Exposure: 0.1~2 seconds, Frequency: 30KHz.
  • Rated Power: 60VA, Focal Spot To Skin Distance: 130mm.
  • Tube focus: 0.3mm, Charger Input Voltage: AC 100V~240V, ±10%.
  • Output Voltage: DC 16.8V, Battery: DC 14.8V, 6400mAh.
  • G.W: 4.8KG, Package size: 330*310*230mm.
  • Relative humidity: <75%RH.
Features of DX10P:
  • Portable high-frequency DC dental x-ray unit, small, light, and nearly no radiation.
  • Easy operation with manual buttons on the shell surface.
  • Suitable for oral pre-treatment diagnosis, especially for dental implant surgery.
  • Durable battery capable of taking about 500 images after a full charge.
  • Compatible with intra-oral digital x-ray imaging systems.
Specification For DX10P-A (Grey):
  • Tube voltage: 60KV, Tube current: 1.2mA.
  • Tube focus: 0.4mm, Frequency: 40KHZ.
  • Exposure time: 0-2.5 seconds, Charge voltage: AC 100V-240V, 50/60Hz.
  • Battery: 14.8V, 4400mAh, Leak radiation: Outside one meter ≤0.002mGy/h.
  • Focal spot to skin distance: 140mm, Net weight: 2.6kg.
  • Package size: 280×270×250mm, Gross weight: 5.0kg.
See more

Catalog excerpts

JADE-S2-1

Portable High-frequency Dental X-ray Model: DX10P-A, DX10P-B Features: 1) DX10P is portable high-frequency DC dental x-ray unit, small, light and nearly no radiation. 2) There are manual buttoons installed on the surface of shell, operate easily. All of the components are installed in the central PC board, insulation vacuum and sealed stereotype protection make its brilliant features. 3) The unit mainly suitable for oral pre-treatment diagnosis of internal organization structure and root depth and so on, is indispensable in daily life clinic, especially for dental implant surgery. 4) The battery is durability, it can take about five hundred images after full charged, and it can be charged and discharged for one thousand times in its life. 5) It can be connected with intra-oral digital x-ray imaging system. Dental X-ray Ultrasonic Scaler Ultrasonic Scaler Specifications: Power input: AC 100-240V, 50/60Hz Output power: 8 Watts Frequency range: 24-32 kHz Water pressure: 1-5bar(0.1-0.5Mpa) Weight: 1kg Dimensions: 92*150*215mm Irrigation: External bottle Features: Swiss Technology: 1) Well-Proven system from the inventor of the Piezo method 2) Permanent feedback control and real-time power adjustments for maximum safety and comfort 3) Precise settings and power delivery for scaling, periodontal, endodontic and restorative treatments 4) Up to 32,000 linear instrument movements per second 5) Minimum abrasion fo tooth surfaces due to perfect instrument oscillation control 6) Gentle and comfortable for endo applications 7) More power for restorative procedures 8) Optimum instrument control and efficiency in all applications 9) Powerful swiss module with minimal operating noise 10) Extremely compact Swiss design 11) Ultraslim lightweight handpiece 12) Large selector for effortless and precise settings Shinova Animal Health Specification For DX10P-A(Grey): Tube voltage: 60KV Tube current: 1.2mA Tube focus: 0.4mm Frequency: 40KHZ Exposure time: 0-2.5s Charge voltage: AC 100V-240V, 50/60Hz Battery: 14.8V, 4400mAh Leak radiation: Outside one meter≤0.002mGy/h Focal spot to skin distance: 140mm Net weight: 2.6kg Package size: 280×270×250mm Gross weight: 5.0kg Specification For DX10P-B(Color): Tube Voltage: 60kV Tube Current: 1.5mA Time Exposure: 0.1~2(s) Frequency: 30KHz Rated Power: 60VA Focal Spot To Skin Distance: 130mm Tube focus: 0.3mm Charger Input Voltage: AC 100V~240V, ±10% Output Voltage: DC 16.8V G.W: 4.8KG Package size: 330*310*230mm Relative humidity: <75%RH Battery: DC 14.8V, 6400mAh