Anesthesia Ventilator Specifications: Driven Mode: Pneumatically driven electronically controlled Respiration Mode: IPPV, Manual Tidal Volume: 50~1600ml I:E Ratio: 1:2 Respiration Frequency: 3-40bpm TV Monitoring: Small animal bellows: 0~300ml Big animal bellows: 300~1600ml Airway Pressure: -20~100H₂O Gas Source Gauge: 0~1Mpa Gauge: O₂ Monitoring: Inspiratory indicator, Expiratory indicator, Power indicator Model: LifeSaver-A Specifications: Driven Mode: Pneumatically driven electronically controlled Respiration Mode: IPPV, Manual Display: high light LED digital display Tidal Volume: 50~1500ml I:E Ratio: 4:1~1:6 Respiration Frequency: 1-90bpm Monitoring Parameters: TV(tidal volume), MV(minute ventilation) Model: LifeSaver-B Anesthesia Ventilator Specifications: Respiration Mode: IPPV, SIMV, Manual Display: 5.5 inch SNT screen Waveform: P-t, V-t Tidal Volume: 50~1600ml I:E Ratio: 8:1~1:8 Respiration Frequency: 1~65bpm Monitoring Parameters: TV(tidal volume), MV(minute ventilation), AP(airway pressure) Animal Ventilator Anesthesia Ventilator Anesthesia Ventilator Portable Ventilator for Small Animals Model: ResBox-V Feature: 1) When the ventilation technique with open high frequency and low humidify volume is adopted, the airway pressure is low with little effect on blood stream returning to its heart and the effect of oxygen compound is good and the oxygen partial pressure can be increased rapidly. While the one with regular frequency and great humidify volume is adopted, CO₂ can be ejected easily. 2) Convenient connecting, it can be connected through the nasal and endotracheal tube. 3) The ventilation mode with high frequency and low humidify volume will not easily produce pressure hurt. 4) The effect of oxygen dispersion is so good that the tested beastie can stand for a long time. 5) Adjustable oxygen concentration, the ventilation mode with continuous oxygen stream and good humidifying effect can ensure beastie to respire independently. 6) Be fit for manual ventilation test for monkey, rabbit, dog etc. 7) Configured with multiform ventilation con-duit for beasties or connected with gas source in addition. Specification: Frequency: 8~150 breaths/min I/E ratio: 1:1~1:3 and inverse ratio Driving Pressure: 0~0.08Mpa Gas source: High-pressure oxygen source or air compressor High-pressure gas source: 0.16MPa Output Limit of reductor: not more than 0.16 Mpa Ventilation Mode: HFJV (High Frequency Jet Ventilation), CPAP (Continuous Positive Airway Pressure), Manual Control Mode. Shinova Animal Health

Open the catalog to page 1

All Shinova vet catalogs and technical brochures

  1. Gastrix

    1 Pages

  2. LC-B200

    1 Pages

  3. JADE-S2

    1 Pages

  4. TP01

    1 Pages

  5. DopMeter-100

    1 Pages

  6. CG-4

    1 Pages

  7. Pet cage

    1 Pages

  8. DopScan 12V

    1 Pages

  9. AneBox-V

    1 Pages