Catalog excerpts
DosaJet Computerized dosing unit with direct injection system DosaJet is a fertigation unit with injection dosing system. DosaJet can be CONFIGURED to be installed in parallel with the pump that POWERS the system (SP version), OR connected Directly to the main supply pump (SL version) For installation in disadvantaged areas DosaJet can be powered by a photovoltaic panel and eventually control a generator for its own energy needs. 8 irrigation valves expandable up to 24 1 EC sensors + 1 pH sensor Max. 1 acid dosing channel Max. 2 fertilizer dosing channels Up to 600 l/h dosing channel capacity 24 multifunction irrigation programs Optional climate control (up to 4 zones) DOSAJET can be equipped with countless cultivation and environmental sensors; in fact DOSAJET can manage the climate in the greenhouse by accurately checking the cooling and heating systems, as well as humidification For LONG distances between DOSAJET and the irrigation valves, these can be managed via radio in a safe and reliable way thanks to Spagnol radio system. The mobile modem accessory allows you to receive text messages or calls in case of alarms or anomalies. On DOSAJET with 230 / 240VAC power supply, this accessory combined with the power backup accessory allows YOU to be informed in case of power failure from the network. Like all Spagnol controllers, DOSAJET can also be supervised with Spagnol MC-Cloud and managed through the Web portal or with the Android and iOS app. The connection can be made via a network cable (with internet connection) or by installing the mobile modem accessory. In any case, it is always possible to supervise DOSAJET on-premises (installation on site) using the Spagnol-MCNet supervision software. MIxed cloud/on-premises solutions are also possible DosaJet INSTALLATION MODES: DosaJet SL On irrigation line DosaJet SP On the irrigation pump
Open the catalog to page 1DOSAJET DosaJet-SL base, frequency 50 Hz, installation on irrigation line, electric power 400VAC three phases + neutral (1) SPAGNOL JET-SL unit Product name Electric power DOSAJET-SL for irrigation line pressure up to 2 bar DOSAJET-SL for irrigation line pressure up to 3 bar DOSAJET-SL for irrigation line pressure up to 4 bar DOSAJET-SL for irrigation line pressure up to 5 bar DOSAJET-SL for irrigation line pressure up to 6 bar DOSAJET-SL for irrigation line pressure up to 7 bar DOSAJET-SL for irrigation line pressure up to 8 bar DOSAJET-SL for irrigation line pressure up to 10 bar...
Open the catalog to page 2DOSAJET ACID DOSING CHANNEL (MAX 1) 301016008 Standard Standard dosing channel for acid DN10, for JET units, composed of venturi injector, solenoid valve for acid, net filter and Ø16 mm hose connection. Acid dosing channel DN10 with electronic flow meter, for JET units, composed of venturi injector, acid solenoid valve, electronic flowmeter, net filter and Ø16 mm hose connection. DN10 FERTILIZER DOSING CHANNELS (MAX 2) 301016010 Standard Fertilizer dosing channel standard DN10, for JET units, composed of venturi injector, fertilizer solenoid valve, net filter and Ø16 mm hose connection....
Open the catalog to page 3DOSAJET SENSORS: Code Required sensor input type: S-BUS Radiation sensor for the irrigation by radiation sum (Joule) Temperature and humidity sensor (for fog/mist irrigations) Irrigation line flow sensor Weight scale for automatic irrigation by weight. Drainage quantity sensor Drainage EC/pH sensor EXPANSION BOARDS: Description 8 relay outputs board 4 S-BUS sensor inputs + 6 contact sensor inputs + 2 0-10V analogic output ESH0143 board 8 S-BUS sensor inputs board ACCESSORIES: Description Cellular modem for alarm reporting and cloud service* (*subscription required) Expansion boxes Backup...
Open the catalog to page 4DOSAJET-Specifications DOSAJET-SL/SP– CONTROLLER CAPACITY: See page 154 for software controls number and capacity. See page 157 for software functionality description. DosaJet-SL/SP– SPECIFICATIONS: Impurities in the water Electric cables inlet Ingress protection Electric supply voltages Min/Max limit (1) Exceeding these values results in damaging. DosaJet-SL/SP– DIMENSION AND INLET/OUTLET POSITION: Rear view 132 cm (52)
Open the catalog to page 5DosaJet-SL/SP/SV – STANDARD PACKAGING PALLET + CARTON BOX: Length (A): Minimum temperature: Maximum temperature: Maximum humidity: Do not expose to outside weather, direct sun radiation, salt fog and vibration. In case of sea transportation or other harsh conditions we recommend the use of a wooden box + barrier bag packaging (see below) DosaJet-SL/SP/SV – WOODEN BOX + BARRIER BAG: Length (A): Minimum temperature: Maximum temperature: IMB0123 Do not expose to outside weather, direct sun radiation and vibration.
Open the catalog to page 6All SPAGNOL SRL catalogs and technical brochures
-
Gravimatic
2 Pages
-
UltraLP
4 Pages
-
ServoMix
5 Pages
-
Radio System
3 Pages
-
I-Fenix
4 Pages
-
G-Fenix
4 Pages
-
F-Fenix
4 Pages
-
EvoMix
10 Pages
-
EvoJet
8 Pages
-
DrenaMix
6 Pages
-
Drenamatic
1 Pages
-
DosaMix
6 Pages
-
C-Fenix
5 Pages
-
Ca-Remover Tank
2 Pages
-
Ca-Remover Line
2 Pages
-
BravoMix
10 Pages
-
BravoJet
8 Pages
-
Sensors
10 Pages