DrenaMix - 1

DrenaMix Drainage water mixing units DrenaMix-L: DrenaMix is a mixing unit that mixes drainage and fresh water. It is used for the reuse of the drainage water coming from the cultivations (suitably treated by an ULTRA disinfection unit). For its functioning DrenaMix must be combined with a dosing unit of the series Bravo/Evo. The necessary inputs/outputs have to be considered on the dosing unit. As an option, DrenaMix can be supplied with its own controller installed on board (without having to be combined with a dosing unit) In this way DrenaMix becomes a completely autonomous mixing unit The mixing of the two incoming waters is managed on the basis of a desired EC output (programmed on dosing unit or on-board controller). As an option, by installing a flow sensor on both inputs, it is possible to perform percentage mixing (the EC value is monitored in case of alarm). DrenaMix is available in three versions (L, M, H) according to the type of dosing unit to which it is combined: DrenaMix type Dosing unit type DrenaMix-L BravoMix-L, EvoMix-L DrenaMix-M BravoMix-M, EvoMix-M DrenaMix-H BravoMix-H, BravoMix-HH, EvoMix-H, EvoMix-HH DrenaMix is designed to be installed directly next to the dosing unit whose inlet and outlet connections are already fitted on DrenaMix in the right position. DrenaMix is already equipped with a bypass and a non-return valve to irrigate the crops directly in the event of a failure of the dosing unit. For the proper automatic functioning of the irrigation system, the levels of the tanks that supply DrenaMix have to be measured and checked by the controller. In case of any doubt, refer to your local Spagnol representative.

Open the catalog to page 1
DrenaMix - 2

DRENAMIX DRENAMIX INSTALLATION FUNCTIONAL SCHEME: Electric power OPTIONAL Water level sensors DrenaMix unit Dosa/Bravo/Evo Mix dosing unit 1 x 24VAC outputs 1 x S-BUS sensor input OPTIONAL Flowmeters Water input EC/pH M Water output To cultivation OPTIONAL ON-OFF tank empty sensors 2 x 24VAC outputs 2 x contact inputs Application specific Water Electric power Electric signal DrenaMix electric panel DrenaMix valve to dosing unit DrenaMix motorized mixing valve DrenaMix non-return valve DrenaMix pump OPTIONAL: flowmeters for mixing by water ratio DrenaMix EC+pH S-BUS sensor OPTIONAL: tank...

Open the catalog to page 2
DrenaMix - 3

DRENAMIX DRENAMIX base, frequency 50 Hz, electric power 400VAC three phases + neutral Total power (KW) DRENAMIX-L with EBARA pump 3M32-160/2.2 DRENAMIX-M with EBARA pump 3M50-125/3.0 DRENAMIX-H with EBARA pump 3M65-160/7.5 DRENAMIX-HH with EBARA pump 3M65-160/7.5 DrenaMix base completed of: - Electric pump panel, with main switch and automatic-manual switch. - EC and pH sensors (to connect to S-BUS input sensor on dosing unit) - 1 24VAC input for pump command (from dosing unit) - 2 24VAC input for motorized mixing valve (1 x calve open, 1 x valve close) (from dosing unit) - 1 free of...

Open the catalog to page 3
DrenaMix - 4

DRENAMIX DRENAMIX – SPECIFICATIONS: L Ø water inlet (both High EC inlet and low EC inlet) 75mm female PVC solvent cement 90mm female PVC solvent cement 90mm female PVC solvent cement Ø water outlet Min. / Max. water temperature Impurities in the water Ingress protection Electric supply voltages Min/Max limit and pump command type (1) Operative max. humidity Operative min. / max. air temperature Exceeding these values results in damaging. DRENAMIX – STANDARD PACKAGING PALLET + CARTON BOX: L Minimum temperature: Maximum temperature: Maximum humidity: Do not expose to outside weather, direct...

Open the catalog to page 4
DrenaMix - 5

DRENAMIX DRENAMIX – DIMENSION AND INPUT/OUTPUT POSITION: DRENAMIX-L: Pipes connection Overall dimension, front view Rear view HIGH EC INPUT Rear view Drenamix-L coupled with open tank dosing unit DRENAMIX-M: Overall dimension, front view Pipes connection Rear view HIGH EC INLET Rear view Drenamix-M coupled with open tank dosing unit

Open the catalog to page 5
DrenaMix - 6

DRENAMIX DRENAMIX – DIMENSION AND INPUT/OUTPUT POSITION: DRENAMIX-H: Overall dimension, front view Pipes connection HIGH EC INLET LOW EC INLET 79.6 cm 34.8 cm Rear view Drenamix-H coupled with open tank dsing unit DRENAMIX-HH: Overall dimension, front view Pipes connection HIGH EC INLET LOW EC INLET 79.6 cm 34.8 cm Rear view Drenamix-HH coupled with open tank dsing unit

Open the catalog to page 6

All SPAGNOL SRL catalogs and technical brochures

  1. Gravimatic

    2 Pages

  2. UltraLP

    4 Pages

  3. ServoMix

    5 Pages

  4. Radio System

    3 Pages

  5. I-Fenix

    4 Pages

  6. G-Fenix

    4 Pages

  7. F-Fenix

    4 Pages

  8. EvoMix

    10 Pages

  9. EvoJet

    8 Pages

  10. Drenamatic

    1 Pages

  11. DosaMix

    6 Pages

  12. DosaJet

    6 Pages

  13. C-Fenix

    5 Pages

  14. BravoMix

    10 Pages

  15. BravoJet

    8 Pages

  16. Sensors

    10 Pages