OVERHEATING PROBEREPLACEMENT
8Pages

{{requestButtons}}

Catalog excerpts

OVERHEATING PROBEREPLACEMENT - 1

OVERHEATING PROBE REPLACEMENT

Open the catalog to page 1
OVERHEATING PROBEREPLACEMENT - 2

7 black clamps Screw-drivers Probe with red connector (spare part) www.tecoonline.com | www.tecous.com

Open the catalog to page 2
OVERHEATING PROBEREPLACEMENT - 3

Disconnect the chiller form power supply. Using the screw-driver, remove the screws indicated in the picture here below (n°16 screws).

Open the catalog to page 3
OVERHEATING PROBEREPLACEMENT - 4

Disconnect ground wire from the cover Remove the cover

Open the catalog to page 4
OVERHEATING PROBEREPLACEMENT - 5

Disconnect the RED probe connector from main board. Cut the black clamps inside the chiller that embrace the probe’s wire.

Open the catalog to page 5
OVERHEATING PROBEREPLACEMENT - 6

Proceed to cut all black clamps that embrace the probe’s wire. Extract the wire from circular passage.

Open the catalog to page 6
OVERHEATING PROBEREPLACEMENT - 7

- Cut the last black clamp that embrace the probe’s wire and copper pipe near condenser - Extract the probe and replace it

Open the catalog to page 7
OVERHEATING PROBEREPLACEMENT - 8

- Insert probe cable in circular passage - Connect new probe connector to main board - Take new seven black plastic clamps and pinch the probe’s cable with the other cables as it was at the beginning. - Place the chiller cover in its position and then place the sixteen screws to close the chiller. ATTENTION: remember to connect ground wire to the cover before closing the chiller.