Overview: The Temposonics® R-Series V RM5 POWERLINK is a high-performance linear position sensor using magnetostrictive technology for precise measurements. It features a robust housing with IP68/IP69 protection, suitable for harsh environments.
Measuring Technology: Utilizes a ferromagnetic waveguide, position magnet, and strain pulse converter to generate a torsional strain pulse, converted into an electrical signal for accurate position measurement.
Key Features:
  • High Precision: Minimum position resolution of 0.5 μm.
  • Multi-Magnet Capability: Measures up to 30 magnets simultaneously.
  • Robust Housing: Stainless steel construction for corrosion resistance and protection.
  • Diagnostics: Provides data such as total distance, internal temperature, and operating hours via POWERLINK.
Technical Specifications:
  • Output Interface: Ethernet POWERLINK with V2 data protocol.
  • Resolution: Selectable from 0.5 to 100 μm.
  • Operating Temperature: -40 to +85 °C.
  • Ingress Protection: IP68/IP69.
  • Shock and Vibration Resistance: Shock tested to 100 g/6 ms, vibration tested to 10 g/10-2000 Hz.
  • EMC Compliance: Meets EN 61000-6-3 and EN 61000-6-2 standards.
Design and Materials: Made from stainless steel 1.4404 (AISI 316L), ensuring durability and RoHS compliance.
Accessories: Includes position magnets, spacers, O-rings, mounting accessories, and cable connectors. Programming tools like TempoLink® and TempoGate® assist in setup and diagnostics.
Ordering Information: Order code specifies model, design, stroke length, number of magnets, connection type, system, and output options. Non-standard stroke lengths available upon request.
Specifications: Minimum distance of 75 mm between magnets is required. Use the same type of magnets for multi-position measurement. Internal linearization requires a suitable magnet.
Delivery: Sensor includes an O-ring; other accessories ordered separately.
Glossary:
  • Extrapolation: Reports data faster than native cycle time.
  • Internal Linearization: Enhances linearity for higher accuracy.
  • Multi-position Measurement: Reports positions of all magnets simultaneously.
  • Node ID: Unique addressing in a POWERLINK network.
  • POWERLINK: Industrial Ethernet interface managed by EPSG.
  • Synchronization Mode: Supports clock-synchronous data exchange.
  • XDD File: XML-based file for device properties and functions.
Contact Information: Contact details for Temposonics offices in various countries are provided.
Trademark Information: Temposonics is a subsidiary of Amphenol Corporation. Trademark details are available on their website.
See more

Catalog excerpts

R-Series V RM5 POWERLINK-1

Data Sheet R-Series V RM5 POWERLINK Magnetostrictive Linear Position Sensors Super shield housing with IP68/IP69 against ingress of dust and water Minimum position resolution 0.5 μm Position and velocity measurements for up to 30 magnets

 Open the catalog to page 1
R-Series V RM5 POWERLINK-2

Temposonics® R-Series V RM5 POWERLINK Data Sheet MEASURING TECHNOLOGY Position magnet (magnetic field) 2 The absolute, linear position sensors provided by Temposonics rely on the company’s proprietary magnetostrictive technology, which can determine position with a high level of precision and robustness. Each Temposonics® position sensor consists of a ferromagnetic waveguide, a position magnet, a strain pulse converter and supporting electronics. The magnet, connected to the object in motion in the application, generates a magnetic field at its location on the waveguide. A short current pulse...

 Open the catalog to page 2
R-Series V RM5 POWERLINK-3

Data Sheet Interface Ethernet POWERLINK Data protocol POWERLINK V2 Measured value Position, velocity/option: Simultaneous multi-position and multi-velocity measurements up to 30 magnets Measurement parameters Resolution: Position Cycle time 1 Stroke length Optional internal linearization: Linearity tolerance (applies Stroke length_ 25.300 mm 300.600 mm for the first magnet for multi-position measurement) 600.1200 mm ± 25 pm_ 1/ Minimum cycle time for multi-position measurements (number of magnets > 2): 400 ps 2/ With position magnet # 251 416-2

 Open the catalog to page 3
R-Series V RM5 POWERLINK-4

Temposonics® R-Series V RM5 POWERLINK Data Sheet TECHNICAL DRAWING RM5-M/-S – RM5 with threaded flange M18×1.5 or ¾"-16 UNF-3A, example: Connection type MXX (cable outlet) Sensor electronics housing 170 (6.7) Threaded flange »M«: M18×1.5-6g Threaded flange »S«: ¾"-16 UNF-3A 100 (3.94) Controlling design dimensions are in millimeters and measurements in ( ) are in inches Fig. 2: Temposonics® RM5 with ring magnet STRUCTURE The RM5 POWERLINK consists of (Fig. 3) Super shield housing R-Series V sensor with connector outlet (connection type D58) Cable for direct connection to the controller (connection...

 Open the catalog to page 4
R-Series V RM5 POWERLINK-5

Temposonics® R-Series V RM5 POWERLINK Data Sheet CONNECTOR WIRING MXX Port 1 – Signal M12 female connector (D-coded) Port 2 – Signal M12 female connector (D-coded) Power supply Cable

 Open the catalog to page 5
R-Series V RM5 POWERLINK-6

Temposonics® R-Series V RM5 POWERLINK Data Sheet FREQUENTLY ORDERED ACCESSORIES – Additional options available in our Accessories Catalog Ring magnet OD33 Part no. 201 542-2 Ring magnet OD25.4 Part no. 400 533 Ring magnet Part no. 402 316 Material: PA ferrite GF20 Weight: Approx. 11 g Surface pressure: Max. 40 N/mm2 Fastening torque for M4 screws: 1 Nm Operating temperature: −40…+105 °C (−40…+221 °F) Material: PA ferrite GF20 Weight: Approx. 14 g Surface pressure: Max. 40 N/mm2 Fastening torque for M4 screws: 1 Nm Operating temperature: −40…+105 °C (−40…+221 °F) Material: PA ferrite Weight: Approx....

 Open the catalog to page 6
R-Series V RM5 POWERLINK-7

Data Sheet M12 A-coded female connector (4 pin/5 pin), straight Part no. 370 677 M12 D-coded male connector M12 connector end Material: Zinc nickel-plated Termination: Insulation-displacement Cable 0: 6...7.2 mm (0.2...0.28 in.) Wire: 24 AWG - 22 AWG Operating temperature: Ingress protection: IP65 / IP67 (correctly fitted) Female connectors M12 should be covered by this protective cap Material: Brass nickel-plated Ingress protection: IP67 (correctly fitted) Fastening torque: 0.39.0.49 Nm Termination: Screw Contact insert: CuZn Operating temperature: Ingress protection: IP67 (correctly fitted)...

 Open the catalog to page 7
R-Series V RM5 POWERLINK-8

Data Sheet Cable sets Programming tools Power cable with M12 A-coded female connector (5 pin), straight - pigtail Part no. 370 673 TempoLink® kit for Temposonics® R-Series V TempoGate® smart assistant for Temposonics® R-Series V Part no. TG-C-0-Djot (xx indicates the number of R-Series V sensors that can be connected (even numbers only)) Material: PUR jacket; black Feature: Shielded Cable length: 5 m (16.4 ft) Ingress protection: IP67 (correctly fitted) Operating temperature: • Connect wirelessly via Wi-Fi enabled device or via USB with the diagnostic tool • Simple connectivity to the sensor...

 Open the catalog to page 8
R-Series V RM5 POWERLINK-9

Data Sheet Output Standard stroke length (mm) Ordering steps U 3 0 1 POWERLINK, position and velocity 000Q POWERLINK, position and velocity, internal linearization (1.30 magnet(s)) Standard stroke length (in.) Non-standard stroke lengths are available; must be encoded in 5 mm/0.1 in. increments. • Specify the number of magnets for your application and order the magnets separately. • The number of magnets is limited by the stroke length. The minimum allowed distance between magnets (i.e. front face of one to the front face of the next one) is 75 mm (3 in.). • Use magnets of the same type for multi-position...

 Open the catalog to page 9
R-Series V RM5 POWERLINK-10

Temposonics® R-Series V RM5 POWERLINK Data Sheet GLOSSARY E Extrapolation The native measurement cycle time of a sensor increases with the stroke length. With extrapolation, the sensor is able to report data faster than the native cycle time, independent of the stroke length of the sensor. Without extrapolation, if data is requested faster than the native cycle time, the last measured value is repeated. I Internal Linearization The internal linearization offers an improved linearity for an overall higher accuracy of the position measurement. The internal linearization is set for the sensor during...

 Open the catalog to page 10
R-Series V RM5 POWERLINK-11

UNITED STATES Americas & APAC Region Phone: +1 919 677-0100 E-mail: [email protected] Document Part Number: 552117 Revision A (EN) 10/2024 Temposonics 58513 Lüdenscheid GmbH & Co. KG Phone: +49 2351 9587-0 EMEA Region & India E-mail: [email protected] ITALY Phone: +39 030 988 3819 Branch Office E-mail: [email protected] FRANCE Phone: +33 6 14 060 728 Branch Office E-mail: [email protected] UK Phone: +44 79 21 83 05 86 Branch Office E-mail: [email protected] SCANDINAVIA Phone: + 46 70 29 91 281 Branch Office E-mail: [email protected] CHINA Phone: + 86 21 3405...

 Open the catalog to page 11

All Temposonics GmbH & Co. KG catalogs and technical brochures

  1. E-Series ET SSI

    11  Pages

  2. LD

    8  Pages

  3. C M1

    4  Pages

  4. MH200

    17  Pages

  5. GTE

    7  Pages

  6. V RP5

    10  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.