AIR CIRCULATION FANS
12Pages

{{requestButtons}}

Catalog excerpts

AIR CIRCULATION FANS - 1

AIR CIRCULATION FANS FOR AGRICULTURAL AND INDUSTRIAL APPLICATIONS

Open the catalog to page 1
AIR CIRCULATION FANS - 2

Air circulation fan specifically designed for high airflow capacity. Available in 42’’ and 53’’, its main features are great efficiency and low maintenance costs. The fan housing is available in galvanized or stainless steel (Aeternum 53’’ only) for maximum corrosion resistance and the impeller with 3 or 6 blades. The entire line is tested in our PERIlab and certified by BessLab. Sturdy and practical motor fixing system 4 secure suspension eyes included Propeller hub in steel with corrosion protection Fixing threaded bush (M8) Easy openi

Open the catalog to page 2
AIR CIRCULATION FANS - 3

Technical features EOR 42 - AMCA 230-12 test number Bess Lab: C12082; C12083; C12084; C12085 *Using ANSI/AMCA Standard 230-99 method. **Single phase motors, different voltage and speed regulable motors over transformers are available on request. Note: tested with two safety nets.

Open the catalog to page 3
AIR CIRCULATION FANS - 4

Technical features Dimensions and loading possibilities *Measurement surface according to UNI EN ISO 3744. **The weight depends on choosed configuration. Loading possibilities fully assembled version (FA) TEHMDTECNICP PEPICDLI

Open the catalog to page 4
AIR CIRCULATION FANS - 5

This air circulation fan - currently available in 31’’ and 37’’- uses a direct-driven system that provides greater efficiency by reducing energy losses and also a substantial lowering of the management and maintenance costs. Furthermore, in an environment where a good destratifier is used, greater energy savings result from an improved temperature homogeneity. The fan housing is available in galvanized or stainless steel (Aeternum 31’’ only) for the maximum corrosion resistance and the impeller is manufactured in aluminum alloy “Peraluman”. 4 secure suspension eyes included Direct drive...

Open the catalog to page 5
AIR CIRCULATION FANS - 6

Technical features ERD 31 - ERD 37 using method AMCA 230-15 TEHMDTECNICP PEPICDLI

Open the catalog to page 6
AIR CIRCULATION FANS - 7

This circulation fan meets the needs of those asking for a simple and cost effective fan mainly used for breeding farms. Available in 53’’only, it is well-known for its light structure and its easy installation. The product is tested in our PERIlab and certified by BessLab. Sturdy and pratical motor fixing system 4 secure suspension eyes included BKF 53 - AMCA 230-12 test number Bess Lab.: C12393; C12394 *Measurement surface according to UNI EN ISO 3744. pic C.7 Loading possibilities *Single phase motors, different voltage and speed regulable motors over transformers are available on...

Open the catalog to page 7
AIR CIRCULATION FANS - 8

DIRECT-DRIVEN AIR DESTRATIFIER This air circulation fan, currently available in 31”, uses a direct-driven system that provides greater efficiency by reducing energy losses and also a substantial lowering of the management and maintenance costs. Furthermore, if used as destratifier, greater energy savings result from an improved temperature homogeneity. The product is tested in our PERIlab. SK kit (optional) safety net for propeller, round air diffuser outlet preset for installation of polyethylene duct Features Model Sound pressure level Lpa [dB]* *Measurement surface according to UNI EN...

Open the catalog to page 8
AIR CIRCULATION FANS - 9

ACF line is the ideal product whenever air displacement is required. It is available in 18”and 26” with wall-housing in galvanized steel or stainless steel for maximum corrosion resistance. Produced with highly resistant materials, it has been designed in order to ensure high energy efficiency and excellent versatility. ACF ensures low noise levels to grant productive labor conditions for the workers. The entire line is tested in our PERIlab and certified by BessLab. ACF 18 Direct drive 4 practical eyelets for easy suspension Aereodynamic blades in alluminium alloy Double safety netting ACF...

Open the catalog to page 9
AIR CIRCULATION FANS - 10

ACF 18 - AMCA 230-12 test number Bess Lab: C09053; C09052 *Using ANSI/AMCA Standard 230-99 method. **Single phase motors, different voltage and speed regulable motors over transformers are available on request. Note: the fans are tested with two safety nets. ACF 26SB: fan tested with one safety net. *Measurement surface according to UNI EN ISO 3744. pic C.7 Loading possibilities on pallet Loading possibilities TEHMDTECNICP PEPICDLI

Open the catalog to page 10
AIR CIRCULATION FANS - 11

VERSIONS, SUPPLEMENTS AND ACCESSORIES Blades version aluminium alloy (preferred version for its lightness and strength) aluminium alloy alluminium alloy galvanised steel stainless steel AISI 430 stainless steel AISI 304 (31 - 37- 42 models only available in ALU version) galvanised steel galvanised steel galvanised steel structure and nets in stainless steel AISI 304 (only for models 31-53) stainless steel AISI 304* *only for model 18 and 26SB All three-phase motors can be used with inverter control. All three-phase motors can be used with inverter control. *Speed regulable motor over...

Open the catalog to page 11
AIR CIRCULATION FANS - 12

TEHMDTECNICn PEPICDLI Release - Novembre 2023 TERMOTECNICA PERICOLI S.r.l. Regione Rapalline, 44 - 17031 Albenga, Italia tel. 0182 589006 fax 0182 589005 pit@pericoli.com PERICOLI ASIA PACIFIC Sdn. Bhd. pap@pericoli.com PERICOLI CENTRO AMERICA pca@pericoli.com PERICOLI MIDDLE EAST pme@pericoli.com PERICOLI INDIA Pvt. Ltd. pin@pericoli.com pericoli.com OBSESS' 68 P€R/coo/ are registered trademarks by Termotecnica Pericoli S.r.l.