Product catalog summary
Introduction
The manual provides detailed instructions for the safe operation and maintenance of the Timberwolf TW 13/75G wood chipper, highlighting the importance of reading the manual to prevent injuries and damage.

Purpose and Specifications
The Timberwolf TW 13/75G is designed to chip wood up to 75mm in diameter with a capacity of over 0.75 tonnes per hour. It features a Honda 4-stroke OHV engine with 9.6kW power, air cooling, and weighs 188kg.

Parts Location
Diagrams identify key components such as the rotor housing, engine, and safety switches.

Safe Working Practices
Operators must maintain a 10-meter safety zone and use personal protective equipment. The manual advises against feeding inappropriate materials like stones or metal.

Operating Instructions
Instructions include safe transportation, engine operation, and daily checks. The chipper should be operated at maximum engine speed with operators standing to the side of the feed funnel.

Maintenance and Service
Regular maintenance is essential for performance. The manual provides a service schedule and guidelines for safe maintenance, including blade sharpening.

Warranty and Compliance
The manual includes a warranty statement and an EC Declaration of Conformity Certificate, ensuring compliance with safety standards.

Noise Levels
Noise levels can exceed 80dB, requiring ear protection for operators and those within a 4-meter radius.

Conclusion
The manual emphasizes the importance of adhering to safe practices for the longevity and safety of the wood chipper.
Service Instructions Overview
The document provides detailed service instructions, emphasizing adherence to maintenance standards to avoid invalidating the warranty. It includes a service schedule, safety precautions, and specific maintenance procedures.

Service Schedule
The schedule outlines regular checks and maintenance tasks, specifying intervals for tasks like greasing rotor bearings and replacing spark plugs.

Safety Precautions
Key measures include immobilizing the machine before maintenance, using genuine parts, and handling blades with care. It stresses using lifting equipment for heavy components.

Maintenance Procedures
Instructions cover changing blades, tensioning belts, and greasing rotor bearings, highlighting the need for regular blade sharpening and proper torque settings.

Warranty Information
The warranty section explains the 36-month warranty terms, covering manufacturing defects but excluding normal wear and tear.

Safety Data for Copper Ease
Safety information for Copper Ease is provided, advising on handling precautions and first aid measures.

Decals and Warnings
Various decals and warnings emphasize safety around rotating blades and the importance of using personal protective equipment.
Parts List and Service Records
The document includes detailed parts lists and service records for the Timberwolf TW 13/75G model, covering the chassis/rotor housing, engine, funnel/discharge, and rotor.

Chassis/Rotor Housing
Includes components like the front plate and main rotor housing.

Engine
Lists parts such as the fuel cap, spark plug, and Honda engine.

Funnel/Discharge
Details parts like the funnel and discharge bucket.

Rotor
Includes parts like the rotor and fan blade.

Service and Warranty Records
Templates for recording service and warranty checks are provided, emphasizing the importance of authorized dealer stamps.

Contact Information
Contact details for Timberwolf are provided for further inquiries or support.
See more

Catalog excerpts

TW-13-75G-1

INSTRUCTION MANUAL timberwolf-uk.com

 Open the catalog to page 1
TW-13-75G-2

© Copyright Entec Industries Ltd 2015 The content of this publication may not be copied, reproduced, republished, posted, broadcast, transmitted or used in any way in any medium without the written permission of Entec Industries Ltd.

 Open the catalog to page 2
TW-13-75G-3

TIMBERWOLF TW 13/75G Section Page No. MACHINE DIMENSIONS & SPECIFICATIONS 2 PARTS LOCATION DIAGRAMS 3 Operator’s Personal Protective Equipment Required 5 Basic Woodchipping Safety 5 General Safety Matters - Do’s and Dont’s 6 Operator’s Personal Protective Equipment Required 8 Daily Checks Before Starting 9 Safe Lifting of Chipper 13 Copper Ease Safety Information 13 Engine Manufacturer’s Handbook 13 Tension Drive Belts 15 Greasing Rotor Bearings 15 EC DECLARATION OF CONFORMITY CERTIFICATE 17 V- BELT TENSIONING TABLE 21 WARRANTY SERVICE CHECK RECORD...

 Open the catalog to page 3
TW-13-75G-4

Thank you for choosing Timberwolf. Timberwolf chippers are designed to give safe and dependable service if operated according to the instructions. IMPORTANT HEALTH AND SAFETY INFORMATION Before using your new chipper, please take time to read this manual. Failure to do so could result in: - PERSONAL INjURY - EqUIPMENT DAMAGE - DAMAGE TO PROPERTY - 3RD PARTY INjURIES This manual covers the operation and maintenance of the Timberwolf TW 13/75G. All information in this manual is based on the latest product information available at the time of purchase. All the information you need to operate the...

 Open the catalog to page 4
TW-13-75G-5

Designed to chip solid wood material up to 75mm in diameter and capable of chipping over 0.75 tonnes of brushwood per hour. 1600 mm, (815 mm with funnel removed) The serial number can be found on the identification plate located on the side of the rotor housing. 1565mm (815mm with funnel removed) Engine type: Maximum power: Cooling method: Overall weight: Starting method: Type of feed: Honda 4 stroke OHV 9.6kW (13hp) Air cooled 188kg Recoil Gravity Maximum diameter material: 75 mm (3”) Fuel capacity: 6.5 litres Material processing capacity: 0.75 tonnes/hr Fuel type: Unleaded petrol

 Open the catalog to page 5
TW-13-75G-6

PARTS LOCATOR DISCHARGE HANDLE DISCHARGE BUCKET TOP ROTOR HOUSING BELT GUARD OPENING HANDLE ROTOR HOUSING CATCH BOLT SAFETY SWITCH PETROL TANK AIR FILTER COVER ENGINE

 Open the catalog to page 6
TW-13-75G-7

PARTS LOCATOR REAR BEARING HOUSING CUTTER BLADE ROTOR DRIVE PULLEY ENGINE PROTECTOR ENGINE PULLEY

 Open the catalog to page 7
TW-13-75G-8

SAFE WORKING The chipper will feed material through on its own. To do this, it relies on sharp blades both on the feed rollers and the chipper rotor. To keep the blades sharp, only feed the machine with clean brushwood. DO NOT put muddy/dirty wood, roots, potted plants, bricks, stones or metal into the chipper. OPERATOR'S PERSONAL PROTECTIVE EQUIPMENT REQUIRED Chainsaw safety helmet fitted with mesh visor and recommended ear defenders to the appropriate specifications. Close fitting heavy-duty non-snag clothing. Work gloves with elasticated wrist. Face mask if appropriate. Steel toe cap safety...

 Open the catalog to page 8
TW-13-75G-9

SAFE WORKING GENERAL SAFETY MATTERS ALWAYS stop the chipper engine before making any adjustments, refuelling or cleaning. DO NOT operate chipper unless available light is sufficient to see clearly. ALWAYS check rotor has stopped rotating and remove chipper ignition key before maintenance of any kind, or whenever the machine is to be left unattended. DO NOT use or attempt to start the chipper without the feed funnel, guards and discharge unit securely in place. ALWAYS operate the chipper with the engine set to maximum speed when chipping. ALWAYS check the machine is well supported and cannot move....

 Open the catalog to page 9
TW-13-75G-10

SAFE WORKING NOISE TEST MACHINE: TW 13/75G NOTES: Tested chipping 40mm x 40mm corsican pine 1.5m in length Noise levels above 80dB (A) will be experienced at the working position. Wear ear protection at all times to prevent possible damage to hearing. All persons within a 4 metre radius must also wear good quality ear protection. 90 .3d B Guaranteed Sound Power: 120dB (A) As required by Annex III of Directive 2000/14/EC “Noise Emission in the environment by equipment for use outdoors”

 Open the catalog to page 10
TW-13-75G-11

OPERATING INSTRUCTIONS SAFE TRANSPORTATION THE TW 13/75G chipper may be transported as a unit or with the feed funnel removed. TAKE care when loading the TW 13/75G as it is 183 kg in weight. STRAP the chipper down firmly before beginning a journey (do not use feed funnel handles to strap down machine). ENSURE no debris or water is trapped in the rotor housing that may spill during transit. TURN the fuel valve OFF and keep the engine upright. All Timberwolf TW 13/75G machines have a full pre - delivery inspection before leaving the factory and are ready to use. Read and understand this instruction...

 Open the catalog to page 11
TW-13-75G-12

OPERATING INSTRUCTIONS MOvE the throttle control lever to idle and allow to run for one minute. TURN the fuel valve to the ‘OFF’ position. EMERGENCY STOPPING Turn the ignition switch to the 'Off' position (as shown above). DAILY CHECKS BEFORE STARTING LOCATE the machine on firm level ground. CHECK engine oil level. CHECK the fuel valve is open. CHECK all guards are in place. CHECK the discharge unit is pointing in a safe direction. CHECK the feed funnel to ensure no objects are inside. For parts location see diagrams on pages 3 & 4. Do not use or attempt to start the chipper without the protective...

 Open the catalog to page 12
TW-13-75G-13

OPERATING INSTRUCTIONS BLADE WEAR The most important part of using a wood chipper is keeping the cutter blades sharp. Timberwolf chipper blades are hollow ground to an angle of 40 degrees. When performing daily blade checks ensure blade edge is sharp and free from chips, if there is any evidence of damage, or the edge is “dull” change the blade(s). The TW 13/75G is fitted with one blade 177 mm (7") long. It is 43 mm wide when new. A new blade should chip for up to 25 hours before it requires sharpening. This figure will be drastically reduced by feeding the machine with stony, sandy or muddy...

 Open the catalog to page 13
TW-13-75G-14

OPERATING INSTRUCTIONS THE FOLLOWING PAGES DETAIL ONLY BASIC MAINTENANCE GUIDELINES SPECIFIC TO YOUR CHIPPER. THIS IS NOT A WORKSHOP MANUAL. THE FOLLOWING GUIDELINES ARE NOT EXHAUSTIvE AND DO NOT EXTEND TO GENERALLY ACCEPTED STANDARDS OF ENGINEERING/MECHANICAL MAINTENANCE THAT SHOULD BE APPLIED TO ANY PIECE OF MECHANICAL EQUIPMENT AND THE CHASSIS TO WHICH IT IS MOUNTED. AUTHORISED TIMBERWOLF SERvICE AGENTS ARE FULLY TRAINED IN ALL ASPECTS OF TOTAL SERvICE AND MAINTENANCE OF TIMBERWOLF WOOD CHIPPERS. YOU ARE STRONGLY ADvISED TO TAKE YOUR CHIPPER TO AN AUTHORISED AGENT FOR ALL BUT THE MOST ROUTINE...