Catalog excerpts
Product Segments • Industrial Motion TiMOTION's JP4 series inline linear actuator is most similar to the JP3, but was designed for industrial applications that require higher load and speed. Its IP69K protection ensures it will withstand high temperature, high pressure water jets, and the ingress of dust and other solid contaminants. For synchronization and position feedback, the JP4 can be equipped with Hall sensors. General Features Max. load Retracted length Output signals Black, grey Operational temperature range Operational temperature range at full performance Storage temperature range
Open the catalog to page 1Standard Dimensions (mm) Retracted Length 14.9 Load and Speed CODE Self Typical Current (A) Typical Speed (mm/s)Typical Current (A) Typical Speed (mm/s) Locking No Load With Load No Load With Load No Load With Load No Load With Load Force (N) 24V DC 24V DC 24V DC 24V DC 12V DC 12V DC 12V DC 12V DC Motor Speed (3800RPM, Duty Cycle 20%: 2min on / 8min off) B Note 1 Please refer to the approved drawing for the final authentic value. 2 This self-locking force level is reached only when a short circuit is applied on the terminals of the motor. All the TiMOTION control boxes have this feature...
Open the catalog to page 2Motor Speed (3800RPM, Duty Cycle 20%: 2min on / 8min off) Speed vs. Load 30.0 Performance Data (24V DC Motor)
Open the catalog to page 3Motor Speed (3800RPM, Duty Cycle 20%: 2min on / 8min off) Speed vs. Load 30.0 Performance Data (12V DC Motor)
Open the catalog to page 4Rear Attachment (mm) See page 7 1 = Aluminum, U clevis, slot 4.2, depth 18.0, hole 10.2 Front Attachment (mm) See page 7 1 = Aluminum, slotless, hole 13.0 Direction of Rear Attachment (Counterclockwise) See page 7 Special Function of Spindle Subassembly Function of Limit Switches See page 8 1 = Two micro switches cut off the actuator at end of stroke 2 = Two micro switches cut off the actuator at end of stroke + third one in between sends signal 3 = Two micro switches send signal at end of stroke 4 = Two micro switches send signal at end of stroke + third one in between sends signal Output...
Open the catalog to page 5JP4 Ordering Key Appendix Retracted Length (mm) 1. Calculate A+B = Y 2. Retracted length needs to ≥ Stroke + Y A. Rear Attachment 1
Open the catalog to page 6JP4 Ordering Key Appendix Rear Attachment (mm) 1 = Aluminum, U clevis, slot 4.2, depth 18.0, hole 10.2 14 Front Attachment (mm) 1 = Aluminum, slotless, hole 13.0 11.5 Direction of Rear Attachment (Counterclockwise) 1 = 0° Hole
Open the catalog to page 7JP4 Ordering Key Appendix Function of Limit Switches Wire Definitions Pin extend (VDC+) retract (VDC+) extend (VDC+) retract (VDC+) extend (VDC+) upper limit switch retract (VDC+) lower limit switch extend (VDC+) upper limit switch medium limit switch retract (VDC+) lower limit switch 100 250 PTC outside the motor; at cable length 100mm, min total cable = 250mm Terms of Use The user is responsible for determining the suitability of TiMOTION products for a specific application. TiMOTION products are subject to change without prior notice.
Open the catalog to page 8