MA6 - 1

Product Segments • Industrial Motion The MA6 series linear actuator, designed by TiMOTION, offers exceptional water ingress protection, available with up to IP67 and IP68 ratings. With a maximum push/ pull force of 8,000N, the MA6 is a robust yet agile solution for applications requiring heavy-duty performance and exceptional durability. Additionally, the MA6 has an optional T-Smart version. Embedded with a driver board, the MA6 allows for easy integration with a variety of control interfaces, eliminating the need for an external control box. The MA6 is available in two T-Smart alternatives: 1) T-Smart Advanced The actuator is controlled by an embedded PCBA, providing advanced functionality and real-time feedback. The T-Smart Advanced configuration allows for synchronization of up to 8 actuators, as well as providing accurate position feedback through a variety of options (Hall, HallPot., PWM). *TiMOTION’s software program, PGMA, exclusively supports the T-smart Advanced configuration, providing the user autonomy to adjust many parameters such as speed, stroke limits, soft-stop, soft-start, and much more. 2) T-Smart Bus Communication The actuator is controlled by the customer's control system, such as their ECU or PLC. - SAE J1939: This protocol provides seamless integration with CAN bus SAE J1939 interfaces, the standardized communication protocol commonly implemented in offroad vehicles and other industrial applications. - Modbus: This is a serial communication protocol predominantly used in industrial automation and process control. The T-Smart Modbus protocol can be smoothly incorporated into existing industrial systems through its interface. General Features Max. load Max. speed at max. load Max. speed at no load Retracted length IP rating Stroke Output signals Voltage Operational temperature range Operational temperature range at full performance Manual drive 8,000N (push/pull) 6.2mm/s 64mm/s ≥ Stroke + 162mm IP69K 25~1000mm Mechanical Pot., adjustable Reed switch, NPN Hall sensors 12/24V DC; 12/24V DC (thermal switch) -40°C~+85°C +5°C~+

Open the catalog to page 1
MA6 - 2

Retracted Length Load and Speed CODE Self Locking Duty Cycle Force (N) Mechenical Brake Note 1 Please refer to the approved drawing for the final authentic value. 2 The current & speed in table are tested with 24V DC motor. With a 12V DC motor, the current is approximately twice the current measured in 24V DC; speed will be similar for both voltages. 3 The current & speed in table are tested when the actuator is extending under push load. 4 The current & speed in table and diagram are tested with a stable 24V DC power supply. 5 Without load, noise level ≤ 78dBA (by TiMOTION test standard,...

Open the catalog to page 2
MA6 - 3

Motor Speed (5100RPM) Speed vs. Load 70.0 Performance Data (24V DC Motor)

Open the catalog to page 3
MA6 - 4

Hardware System Rear Attachment (mm) See page 6 1 = #45 Steel, slotless, hole 10.2 2 = #45 Steel, slotless, hole 12.2 3 = #45 Steel, slotless, hole 12.8 4 = #45 Steel, U clevis, slot 8.2, depth 12.5, hole 10.2 5 = #45 Steel, U clevis, slot 8.2, depth 12.5, hole 12.2 6 = #45 Steel, U clevis, slot 8.2, depth 12.5, hole 12.8 7 = #45 Steel, U clevis, slot 8.2, depth 15.0, hole 10.2 8 = #45 Steel, U clevis, slot 8.2, depth 15.0, hole 12.2 9 = #45 Steel, U clevis, slot 8.2, depth 15.0, hole 12.8 B = #SUS 316 Steel, U clevis, slot 8.2, depth 12.5, hole 10.2 Front Attachment (mm) See page 6-7 1 =...

Open the catalog to page 4
MA6 - 5

MA6 Ordering Key Appendix Retracted Length (mm) 1. Calculate A+B+C = Y 2. Minimum retracted length is Stroke+Y Note 1 Depending on the attachments, the motor cover might interfere with the customer's device when retracted length is between 225~318mm. Please confirm before placing order. Front Attach. Output Signal Load & Speed Type (N) B, C, D, E

Open the catalog to page 5
MA6 - 6

MA6 Ordering Key Appendix Rear Attachment (mm) 2 = #45 Steel, slotless, hole 12.2 12.5 B = #SUS 316 Steel, U clevis, slot 8.2, depth 12.5, hole 10.2 12.5 8 = #45 Steel, U clevis, slot 8.2, depth 15.0, hole 12.2 9 = #45 Steel, U clevis, slot 8.2, depth 15.0, hole 12.8 7 = #45 Steel, U clevis, slot 8.2, depth 15.0, hole 10.2 6 = #45 Steel, U clevis, slot 8.2, depth 12.5, hole 12.8 5 = #45 Steel, U clevis, slot 8.2, depth 12.5, hole 12.2 4 = #45 Steel, U clevis, slot 8.2, depth 12.5, hole 10.2 3 = #45 Steel, slotless, hole 12.8 1 = #45 Steel, slotless, hole 10.2 7 = #45 Steel, U clevis, slot...

Open the catalog to page 6
MA6 - 7

MA6 Ordering Key Appendix Front Attachment (mm) B = #SUS 316 Steel, slotless, hole 10.2 9 = #45 Steel, U clevis, slot 8.2, depth 15.0, hole 12.8 8 = #45 Steel, U clevis, slot 8.2, depth 15.0, hole 12.2 Direction of Rear Attachment (Counterclockwise) 3 = 90° Connector (mm) 01 = Tinned leads, unsheathed wire 50, strippe

Open the catalog to page 7
MA6 - 8

MA6 Ordering Key Appendix Wire Definition Normal Port Number Function of Limit Switches Wire Color 1. T wo Micro Switches Cut ● RD Off the Actuator ● BK Output Signal 0. Without 2. T wo Micro Switches Cut ● RD Off the Actuator + 3rd ● BK Micro Switch ● RD 3. Two Micro Switches Send Signal 6. T wo Limit Switches Cut ● RD Off the Actuator and ● BK Send Signal at End of Stroke (Signal Type: ● RD Normally Open) ● WH * Limit switch #6 could not ch

Open the catalog to page 8
MA6 - 9

MA6 Ordering Key Appendix Wire Definition #T_T-Smart Direct Cable Out, 1+1 Type: Military Connector (A1) + Molex 6P Connector (P2) (T-Smart Dedicated Option) Port Wire Color Power ground Ctrl - Extend Ctrl - Retract Hall-Pot./ Hall A/ Commu. A Signal ground For programming or wireless accessories. * Control motor movement: when Vcc wire is short circuit with Ctrl-Entend / Ctrl-retract wire. Terms of Use The user is responsible for determining the suitability of TiMOTION products for a specific application. TiMOTION products are subject to chan

Open the catalog to page 9

All Timotion Europe catalogs and technical brochures

  1. TA29AC

    7 Pages

  2. TA29

    8 Pages

  3. TA26

    6 Pages

  4. TA10

    8 Pages

  5. TA9

    11 Pages

  6. TA6

    10 Pages

  7. TA5P

    7 Pages

  8. TA4

    11 Pages

  9. TA2PAC

    8 Pages

  10. TA2P

    12 Pages

  11. TA2

    10 Pages

  12. MA5

    11 Pages

  13. MA4

    8 Pages

  14. MA3

    9 Pages

  15. JP6

    7 Pages

  16. JP4

    8 Pages

  17. JP3

    9 Pages