Catalog excerpts
Product Segments • Care Motion TiMOTION’s TA10 series linear actuator is primarily used in the medical market. This actuator series handles high loads and is designed with a manual crank attachment. If necessary, medical staff will be able to easily operate the manual crank to adjust the patient bed. In addition, this linear actuator is available with an optional IP54 or 66 rating. General Features Max. load Retracted length Hall sensor(s) Black, grey Operational temperature range With manual crank functi
Open the catalog to page 1Load and Speed CODE Self Locking Force (N) Motor Speed (2600RPM, Duty Cycle 10%) D Motor Speed (3400RPM, Duty Cycle 10%) L Note 1 Please refer to the approved drawing for the final authentic value. 2 This self-locking force level is reached only when a short circuit is applied on the terminals of the motor. All the TiMOTION control boxes have this feature built-in. 3 The current & speed in table are tested when the actuator is extending under push load. 4 The current & speed in table and diagram are tested with TiMOTION control boxes, and there will be around 10% tolerance depending on...
Open the catalog to page 2Motor Speed (2600RPM) Speed vs. Load 40.0 35.0 30.0 Performance Data (24V DC Motor)
Open the catalog to page 3Motor Speed (3400RPM) Speed vs. Load 40.0 35.0 30.0 Performance Data (24V DC Motor)
Open the catalog to page 4Rear Attachment (mm) See page 7 1 = Aluminum CNC, without slot, hole 10.2, for hand crank 2 = Aluminum CNC, without slot, hole 12.2, for hand crank Front Attachment (mm) See page 7 1 = Casting, width 32, hole 10.2 Direction of Rear Attachment (Counterclockwise) See page 7 Functions for Limit Switches See page 8 1 = Two switches at full retracted / extended positions to cut current 2 = Two switches at the retracted / extended positions to cut current with the third one in between to send signal 3 = Two switches at the retracted / extended positions to send signal 4 = Two switches at the...
Open the catalog to page 5TA10 Ordering Key Appendix Retracted Length (mm) 1. Calculate A = Y 2. Retracted length needs to ≥ Stroke+Y *Retracted length : S + 188 B. Stroke (mm)
Open the catalog to page 6TA10 Ordering Key Appendix Rear Attachment (mm) 1 = Aluminum CNC, without slot, hole 10.2, for hand crank 2 = Aluminum CNC, without slot, hole 12.2, for hand crank Front Attachment (mm) 1 = Casting, width 32, hole 10.2 2 = Casting, width 32, hole 12.2 Direction of Rear Attachment (Counterclockwise) 1 = 0°
Open the catalog to page 7TA10 Ordering Key Appendix Functions for Limit Switches Wire Definitions CODE extend (VDC+) retract (VDC+) extend (VDC+) retract (VDC+) extend (VDC+) upper limit switch retract (VDC+) lower limit switch extend (VDC+) upper limit switch medium limit switch retract (VDC+) lower limit switch Terms of Use The user is responsible for determining the suitability of TiMOTION products for a specific application. TiMOTION products are subject to change without prior notice.