Catalog excerpts
Product Segments • Care Motion • Ergo Motion TiMOTION’s TA29 is one of our new generation medical DC linear actuators, which can lift up to 6000N, yet has a small installation dimension. In addition to this, its IP rating is up to IP66W. The TA29 is highly recommended for various medical applications that require a short retracted length, yet need to support a large force, such as the leg adjustment or sling angle actuator on the patient hoist system. General Features Max. load Retracted length ≥ 178mm (depending on chosen options) Output signals Black, grey Operational temperature range Suitable for patient hoist applica
Open the catalog to page 1Retracted Length Load and Speed CODE Self Locking Force (N) Motor Speed (4800RPM, Duty Cycle 10%) B Motor Speed (5200RPM, Duty Cycle 10%) H Note 1 Please refer to the approved drawing for the final authentic value. 2 The current & speed in table are tested when the actuator is extending under push load. 3 This self-locking force level is reached only when a short circuit is applied on the terminals of the motor. All the TiMOTION control boxes have this feature built-in. 4 The current & speed in table are tested with 24V DC motor. With a 12V DC motor, the current is approximately twice the...
Open the catalog to page 2Motor Speed (4800RPM, Duty Cycle 10%) Speed vs. Load 35.0 Performance Data (24V DC Motor)
Open the catalog to page 3Motor Speed (5200RPM, Duty Cycle 10%) Speed vs. Load 35.0 Performance Data (24V DC Motor)
Open the catalog to page 4Rear Attachment (mm) See page 7 3 = Aluminum casting, U clevis, slot 6.2, depth 12.2, hole 10.2 4 = Aluminum casting, U clevis, slot 6.2, depth 12.2, hole 12.2 Front Attachment (mm) See page 7 3 = Aluminum CNC, without slot, hole 10.2 4 = Aluminum CNC, without slot, hole 12.2 Direction of Rear Attachment (Counterclockwise) See page 7 Special Functions for Spindle SubAssembly 0 = Without (Standard) 1 = Safety nut Functions for Limit Switches See page 8 1 = Two switches at full retracted / extended positions to cut current 2 = Two switches at full retracted / extended positions to cut current...
Open the catalog to page 5TA29 Ordering Key Appendix Retracted Length (mm) 1. Calculate A+B+C+D = Y 2. Retracted length needs to ≥ Stroke + Y 3. Retracted length needs to > 178mm A. Front Attachment 3, 4
Open the catalog to page 6TA29 Ordering Key Appendix Rear Attachment (mm) 3 = Aluminum casting, U clevis, slot 6.2, depth 12.2, hole 10.2 4 = Aluminum casting, U clevis, slot 6.2, depth 12.2, hole 12.2 Front Attachment (mm) 3 = Aluminum CNC, without slot, hole 10.2 4 = Aluminum CNC, without slot, hole 12.2 Direction of Rear Attachment (Counterclockwise) 1 = 90°
Open the catalog to page 7TA29 Ordering Key Appendix Functions for Limit Switches Wire Definitions CODE extend (VDC+) retract (VDC+) extend (VDC+) retract (VDC+) extend (VDC+) upper limit switch retract (VDC+) lower limit switch extend (VDC+) upper limit switch medium limit switch retract (VDC+) lower limit switch extend (VDC+) upper limit switch retract (VDC+) lower limit switch C = Y cable (for direct cut system, water proof, anti pull) Cable Length for Direct Cut System (mm) Terms of Use The user is responsible for determining the suitability of TiMOTION products for a specific application. TiMOTION products are...