FENIX 3000/3; 3000/4; 3000/6; 4000/6
28Pages

{{requestButtons}}

Catalog excerpts

FENIX 3000/3; 3000/4; 3000/6; 4000/6 - 1

USER MANUAL Combination seed drill UTS DRILL control for: FENIX 3000/3; 3000/4; 3000/6; 4000/6 UNIA Sp. z o.o. Ul. Fabryczna 2, 49 – 301 BRZEG, POLAND Phone +48 77 444 45 86 | Service: + 48 77 444 45 11 | Read the User Manual and follow the safety instructions contained in it before operating the machine. To access the Parts Catalogue and Guarantee Card, scan the QR code on the machine type plate. Remember to register the guarantee or contact your dealer to do so.

Open the catalog to page 1
FENIX 3000/3; 3000/4; 3000/6; 4000/6 - 3

UTS DRILL User Manual Read the User Manual carefully, and then familiarise yourself with the construction and operation of the control system and its assemblies. Accurate adherence to the instructions contained in this Manual will ensure long-term, efficient, trouble-free and safe operation. In case of any problems and doubts with the operation and use, please contact an authorized dealer or the manufacturer’s Sales Department. The technical safety requirements are only met if only original spare parts are used in the event of repair. ATTENTION: The User Manual for the UTS DRILL control is...

Open the catalog to page 3
FENIX 3000/3; 3000/4; 3000/6; 4000/6 - 4

UTS DRILL User Manual The manufacturer is not responsible for any damage to property or people resulting from non-compliance with the recommendations. All responsibility and risk associated with it rests with the user. The rules of use consistent with the intended use of the product also include compliance with all the conditions of use described by the manufacturer. Observe the recognized health and safety rules and other rules of safe work in industry, agriculture and the road code. Any modifications to the machine carried out by the user exclude the liability of the manufacturer. 1.4....

Open the catalog to page 4
FENIX 3000/3; 3000/4; 3000/6; 4000/6 - 5

UTS DRILL User Manual Track marker control. Control of all hydraulic functions (lifting, folding, adjustments, fan). Control of process path valves. Pre-emergence path control. Start the calibration test via the test switch. Registering the speed and correct operation of machine elements. Blower speed monitoring. Monitoring of sowing, and the possibility of changing the dose during operation. 3.2. Control assembly. The system comprises the following components: • A job computer that is mounted on the seed drill and controls its operation. Signal splitter ISOBUS cable CAN connection Sensors...

Open the catalog to page 5
FENIX 3000/3; 3000/4; 3000/6; 4000/6 - 6

UTS DRILL User Manual Rotation sensors. (Hall generator) Schematic view Mounting angle Ring with magnets Capacitive sensors. The signal is sent when the flat top side of the sensor is covered, e.g. by seeds. Schematic view Flat top side of the sensor LED; indicates if the sensor is connected Capacitive sensor Wire clips Set screw for changing the switching distance

Open the catalog to page 6
FENIX 3000/3; 3000/4; 3000/6; 4000/6 - 7

UTS DRILL User Manual INSTRUCTIONS FOR THE CONTROL OF THE SEEDING FUNCTIONS 1. Connecting the computer. To connect the job computer to the power supply and to the ISOBUS terminal, you must connect the ISOBUS cable to the ISOBUS connection on the tractor. 1. Take the ISOBUS cable for the job computer. 2. Unscrew the dust cap. 3. Insert the ISOBUS plug into the ISOBUS connection on the tractor. 4. Lock the plug. For Müller-Elektronik basic equipment, in order to do this, turn the plug clockwise. Depending on the design version, you must proceed differently with other ISOBUS basic equipment....

Open the catalog to page 7
FENIX 3000/3; 3000/4; 3000/6; 4000/6 - 8

UTS DRILL User Manual Structure of the seed drill work screen Information on metering drives Active additional functions Information about the condition of the drill Information on metering drives. In this area you can see: • • - dose applied to each connected metering drive. The number indicates the relevant metering drive. The current value appears here. - entered percentage change of the desired value. Information on the rows. In this area you can see: • Rows where the seed and fertiliser application is performed. Arrangement of process paths Information on additional functions. This...

Open the catalog to page 8
FENIX 3000/3; 3000/4; 3000/6; 4000/6 - 9

UTS DRILL User Manual - the hopper reports an alarm (grain/fertiliser level). - the machine is in the working position. Information on additional functions. In this area you can see: • - the current speed of the machine. - the current rotational speed of the blower. The number indicates which blower it applies to. - creation of a process path. - deactivation of the control of the process path creation system. Operation of the machine in the field. 3.1. Hopper discharge. If there are still residues in the hopper after work, the hopper can be emptied. Make sure that the sowing process is...

Open the catalog to page 9
FENIX 3000/3; 3000/4; 3000/6; 4000/6 - 10

UTS DRILL User Manual 2. Select the product for which you want to perform a calibration test. 3. – press. The “Calibration test” screen appears. 4. Select the dispenser for which the calibration test is to be carried out (if the seed drill does not have the option to spread fertiliser, the selection will not be active). 5. In the input field below the text “Working speed” enter the speed at which the sowing run is to be carried out later. 6. Enter the calibration factor, if is known to you. For new products, the optimal calibration factor is calculated automatically. It is then advisable to...

Open the catalog to page 10
FENIX 3000/3; 3000/4; 3000/6; 4000/6 - 11

UTS DRILL User Manual - start sowing. Stop sowing. - finish sowing. The work screen shows the message: “Work interrupted.” All metering drives are stopped. 3.6. Turning the blower on and off. The blower can be turned on or off during operation. A different function symbol appears on the work screen, depending on the current status. 1. - turn on the blower or - turn off the blower. Note: The value of the blower revolutions is entered in the product menu. 3.7. Adaptation of the desired value during operation. The desired value can be adjusted during operation. If you are working with several...

Open the catalog to page 11
FENIX 3000/3; 3000/4; 3000/6; 4000/6 - 12

UTS DRILL User Manual Areas of the drill work screen that are important for creating process paths. A process path is created on the left side of the machine. A process path is created on the right side of the machine. Process path rhythm length Number of runs until the process path rhythm is repeated. Operation elements Meaning of symbols Function symbol Meaning Increases the run number. For example, to be able to continue working on the same run after leaving the field. This function symbol is only displayed when metering is stopped or the operating conditions are met. Reduces the run...

Open the catalog to page 12

All Unia catalogs and technical brochures

  1. MAX/MAX T

    30 Pages

  2. ARES L

    34 Pages

  3. POLONEZ

    16 Pages

  4. PLOW

    34 Pages