your Hydraulic Brand INTRODUCTION Gear pumps from Vincke have a floating bushing feature with automatic axial clearance compensation. The bushings are made with special abrasion resistant material providing improved service life. Precisely machined gears ensure our units provide excellent low noise characteristics. Our cold extrusion motor bodies can endure pressures above 30Mpa. High strength cast iron front & rear covers also enhance our reliability. Our units are widely used in the industrial, mobile, marine and aerospace industries. CHARACTERISTICS Vincke gear pumps are produced in 5...

Open the catalog to page 3
VINCKE HYDRAULICS GEAR PUMPS - 4

your Hydraulic Brand FILTER RECOMMENDATION • By far largest number of premature failures of gear pumps is due to contamination; filtering with clogging indicating and alarms are recommended. • The initial contamination of the fluid must not exceed class 10 NAS 1638,pass experience has shown that even brand new fluid often exceed this value in this case it is recommended below: 60µm inlet , and in the return side: Standard PRESSURE DEFINITION INLET PRESSURE P3= peak max. pressure P2= intermittent max. pressure P1= continuous max. pressure Under standard working conditions, intake pipe...

Open the catalog to page 4
VINCKE HYDRAULICS GEAR PUMPS - 5

your Hydraulic Brand DESIGN CALCULATIONS FOR PUMP Q= flow rote (l/m) M = torque P = power N = speed r/min A = inside area of pipe (cm2) v = Q / 6 • A (m/s) V= displacement [cm3/rotation] n = rota/ion speed [rotations per minute] ηvol = pump volumetric efficiency, take 0.95 as an indicative value for rotation speeds ranging between 1.000 and 2000 rpm. ΔP = pressure differential (bar) ηhm = hydromechanical efficiency, take 0.80 as indicative value under cold conditions and 0.85 under working conditions. ηtot = total pump efficiency (ηhm • ηvol) Fluid velocity Calculate the velocity (v) of a...

Open the catalog to page 5
VINCKE HYDRAULICS GEAR PUMPS - 6

your Hydraulic Brand VNK0 GEAR PUMP GROUP 0 End cover: G1 / 4 thread depth 12. To mount the pump, n.2 M5 screws, with a torque wrench setting fixed at 5.4±0.5 Nm. HOW TO ORDER Single pump Inlet port Outlet port Counter clockwise

Open the catalog to page 6
VINCKE HYDRAULICS GEAR PUMPS - 7

your Hydraulic Brand

Open the catalog to page 7
VINCKE HYDRAULICS GEAR PUMPS - 8

your Hydraulic Brand VNK1 GEAR PUMP GROUP 1 HOW TO ORDER Single pump Inlet port * Outlet port * * see specifications of shafts, flanges and ports in pages 12, 13. Counter clockwise

Open the catalog to page 8
VINCKE HYDRAULICS GEAR PUMPS - 9

your Hydraulic Brand End cover: G3/8 thread depth 12. To mount the pump, n.2 M8 srews, with a torque wrench setting fixed at 27±3 Nrn.

Open the catalog to page 9
VINCKE HYDRAULICS GEAR PUMPS - 10

your Hydraulic Brand M6 threads depth 12. To mount the pump, n.2 M8 screws, with a torque wrench setting fixed at 27 ±3 Nm.

Open the catalog to page 10
VINCKE HYDRAULICS GEAR PUMPS - 11

your Hydraulic Brand M6 thread depth 12. To mount the pump, n.4 MB screws, with a torque wrench setting fixed at 27 ±3 Nm. Shaft M7 nut, with a torque wrench setting fixed at 8 Nm.

Open the catalog to page 11
VINCKE HYDRAULICS GEAR PUMPS - 12

your Hydraulic Brand FRONT COVERS

Open the catalog to page 12
VINCKE HYDRAULICS GEAR PUMPS - 13

your Hydraulic Brand

Open the catalog to page 13
VINCKE HYDRAULICS GEAR PUMPS - 14

your Hydraulic Brand VNK2 GEAR PUMP GROUP 2 HOW TO ORDER Single pump Inlet port * Outlet port * * see specifications of shafts, flanges and ports in pages 22, 23, 24 Counter clockwise

Open the catalog to page 14
VINCKE HYDRAULICS GEAR PUMPS - 15

your Hydraulic Brand M6 thread depth 13, M8 thread depth 17. To mount the pump, n.4 M10 screws, with a torque wrench setting fixed at 70 ...W75 Nm. Shaft M 12x1.25 nut, with a torque wrench setting fixed at 50 Nm. * see specifications of ports in page 24.

Open the catalog to page 15
VINCKE HYDRAULICS GEAR PUMPS - 16

your Hydraulic Brand Screws tightening torque at 70 ... 75 Nm * see specifications of ports in page 24.

Open the catalog to page 16
VINCKE HYDRAULICS GEAR PUMPS - 17

your Hydraulic Brand M6 thread depth 13. To mount the pump, n.4 M10 screws, with a torque wrench setting fixed at 70 ... 75 Nm. Shaft M 12x 1.5 nut, with a torque wrench setting fixed at 50 Nm. * see specifications of ports in page 24.

Open the catalog to page 17
VINCKE HYDRAULICS GEAR PUMPS - 18

your Hydraulic Brand M6 thread depth 13. To mount the pump, n.2 M10 screws, with a torque wrench setting fixed at 45 ... 50 Nm. Shaft M 12x 1.5 nut, with a torque wrench setting fixed at 50 Nm. * see specifications of ports in page 24.

Open the catalog to page 18
VINCKE HYDRAULICS GEAR PUMPS - 19

your Hydraulic Brand M6 thread depth 13. To mount the pump, n.2 M10 screws, with a torque wrench setting fixed at 45 ...50 Nm. Shaft M 12x 1.5 nut, with a torque wrench setting fixed at 50 Nm. * see specifications of ports in page 24.

Open the catalog to page 19
VINCKE HYDRAULICS GEAR PUMPS - 20

your Hydraulic Brand M6 thread depth 13. To mount the pump, n.2 M10 screws, with a torque wrench setting fixed at 45 ...50 Nm. Shaft M 12x 1.5 nut, with a torque wrench setting fixed at 70 Nm. * see specifications of ports in page 24.

Open the catalog to page 20
VINCKE HYDRAULICS GEAR PUMPS - 21

your Hydraulic Brand 8 thread depth 16. To mount the pump, n.4 M10 screws, with a torque wrench setting fixed at 70 ... 75 Nm. * see specifications of ports in page 24.

Open the catalog to page 21
VINCKE HYDRAULICS GEAR PUMPS - 22

your Hydraulic Brand FRONT COVERS

Open the catalog to page 22
VINCKE HYDRAULICS GEAR PUMPS - 23

your Hydraulic Brand FRONT COVERS

Open the catalog to page 23
VINCKE HYDRAULICS GEAR PUMPS - 24

your Hydraulic Brand PORTS CODE PORTS CODE

Open the catalog to page 24
VINCKE HYDRAULICS GEAR PUMPS - 25

your Hydraulic Brand VNK3 GEAR PUMP GROUP 3 HOW TO ORDER Single pump Inlet port * * see specifications of shafts, flanges and ports in pages 28, 29. Outlet port * Counter clockwise

Open the catalog to page 25
VINCKE HYDRAULICS GEAR PUMPS - 26

your Hydraulic Brand M10 thread depth 18, To mount the pump, n.8 M10 screws, with a torque wrench setting fixed at 47±3 Nm. Shaft M 14x 1.5 nut, with a torque wrench setting fixed at 80 Nm. * see specifications of ports in page 29.

Open the catalog to page 26
VINCKE HYDRAULICS GEAR PUMPS - 27

your Hydraulic Brand To mount the pump, n.8 M10 screws, with a torque wrench setting fixed at 47±3 Nm. * see specifications of ports in page 29.

Open the catalog to page 27
VINCKE HYDRAULICS GEAR PUMPS - 28

your Hydraulic Brand FRONT COVERS

Open the catalog to page 28
VINCKE HYDRAULICS GEAR PUMPS - 29

your Hydraulic Brand PORTS CODE PORTS CODE PORTS CODE

Open the catalog to page 29
VINCKE HYDRAULICS GEAR PUMPS - 30

VNK MULTIPLE GEAR PUMP your Hydraulic Brand MULTIPLE PUMPS The VNKBM pumps can be easily transformed in multiple units. All drive shafts are pre-arranged and have a splined end according DIN 5480. The first unit must always be the same size or bigger than following units. The features and performances are the same of the corresponding single units: only in the case of simultaneous operating you have to verify that the inlet torque is lower than the max. transmissible by the drive shaft. Finally to assembly the multiple pump you need to order bolts of the right lenght. Standard Version W S-...

Open the catalog to page 30
VINCKE HYDRAULICS GEAR PUMPS - 31

VNK MULTIPLE GEAR PUMP your Hydraulic Brand VNKBMD - DRIVER PUMP HOW TO ORDER Multiple pump Inlet port * Outlet port * * see specifications of shafts, flanges and ports in pages 42, 43, 44, 45, 46. Standard Version Counter clockwise

Open the catalog to page 31

All VINCKE HYDRAULICS catalogs and technical brochures

  1. CP16GC

    3 Pages

  2. VNK1-*1-1

    3 Pages

  3. GEARBOXES

    26 Pages

  4. IN-LINE VALVES

    45 Pages