BW-2050 Full Kit
11Pages

{{requestButtons}}

Catalog excerpts

BW-2050 Full Kit - 1

Weltech Interna onal Limited The BW‐2050 has been designed to give the operator complete flexibility for manual live bird weighing. The BW‐2050 is ba ery operated and will weigh for up to 15 hours between recharging and will retain all weights even when the ba ery is flat. The BW‐2050 can store up to 5000 bird weights. Weights can be placed into 1‐50 separate stores. All informa on is stored un l the CLEAR sequence has been completed. The maximum weight the unit can weigh is 10kgs (22lbs) for the chicken version and 50kgs (110lbs) for the turkey weigher. BW‐2050 Control Panel Picture is of BW‐2050 Full kit

Open the catalog to page 1
BW-2050 Full Kit - 2

The BW‐2050 is calibrated by Weltech before it leaves the factory. Should you need to calibrate the weigher or set a fixed tare weight if using a shackle then follow the instruc ons below. To reset the weigher back to Factory se ngs hold the MEMORY STORE bu on and turn on. The display will show WELTECH SET UP un l the bu on is released, when the bu on is released FACTORY RESET will be displayed, press ENTER to change se ngs. The display will show DISPLAY STYLE, it can be set to metric or USA by pressing the INC arrow, when set press ENTER, The display will show WEIGHT RANGE and CHICKEN...

Open the catalog to page 2
BW-2050 Full Kit - 3

To set operator se ngs hold the SET UP bu on 100x50 down and turn ON, the display will show WELTECH SET UP when the bu on is released DATA STORES will be displayed, by pressing the INC or DEC arrows the number of houses or pens data is to be stored in can be set, 1x5000 to 100x50, when set press ENTER. SELECT STORE This func on allows the user to select the house or pen in which the bird weights are to be stored. If turned off the weighings will be stored in numerical order. ENABLE BUTTONS Allows full usage of...

Open the catalog to page 3
BW-2050 Full Kit - 4

STABILITY Repe ons within stability jump limit. Do not alter. STABILITY JUMP Varia on in ADC count considered stable do not alter. WEIGHT FILTER Filters out movement on the weigher FILTER JUMP Filters out excessive sharp movements on the weigher WEIGHT FREEZE Shows accepted weight un l ready EVENNESS Percentage above and below average for sta s cs HIGH LIMIT Upper acceptance limit LOW LIMIT Lower acceptance limit ...

Open the catalog to page 4
BW-2050 Full Kit - 5

POWER DOWN If the unit has not been used it will automa cally turn off a er the pre set me. OPERATING INSTRUCTIONS Turn the weigher on by pressing the ON bu on. To clear data already stored in the weigher press CLEAR, the display will then ask you to press ENTER a er this the display will then ask you to confirm by pressing SET UP, to escape press CLEAR. Data will remain in the memory un l cleared. The display will then show : To exit and or store new se ngs press ENTER and then CLEAR. You do not have to go through all the set up. Ba ery indicator will flash when being...

Open the catalog to page 5
BW-2050 Full Kit - 6

BEFORE MOVING THE WEIGHER TURN IT OFF The same procedure is repeated for each house or pen that is to be weighed. SHOW DATA To see weights in any par cular house at any me press SHOW DATA then by pressing the INC or DEC arrows the house number to be checked can be selected. Press Enter and the display will show :  Total number of birds weighed Average weight PRINT OPTIONS Data to be printed can be selected by pressing the PRINT OPTIONS key, the display will show PRINT EVERY BIRD and flash ON, to turn this op on on or off press the INC or DEC arrow then ENTER. The display will then...

Open the catalog to page 6
BW-2050 Full Kit - 7

WELTECH INTERNATIONAL PRINTER OUTPUT CHARGING STATISTICS ON The printout will show: • The date and time weighing was started and finished • Data for each store • Total weighed Average weight EACH ON The printout will print the weight of every bird weighed in order. HYSTORGRAM ON The printout will show all the birds weighed in 20 gram bands. The charging socket and Serial RS232 output connector is situated on the side of the weigher. In the centre of the display is the battery charge indicator. When fully charged the box will go completely black and as the weigher is used the box...

Open the catalog to page 7
BW-2050 Full Kit - 8

A PC may be connected to the RS232 connector to output the data. Once the computer is connected and the so ware is ready to accept data, then press the PRINT DATA to output the data. USB STICK Socket if fi ed (Op onal) Charging Socket ON OFF Tares weight MEMORY STORE Stores data SHOW DATA Displays data PRINT DATA Prints data SET BANDS Set grading bands or target weights FAST/ SLOW RS232 Output Printer & Computer Selects between fast or slow weighing PRINT OPTIONS Clear data stored Set type of printout. Sta s cs, Histogram, Each. Enters data into store/ command Bits per...

Open the catalog to page 8
BW-2050 Full Kit - 9

USING THE USB The following commands are accepted at the serial port. Send id message Send vertical every bird list for current store Send current weight Send summary report for current store Send histogram for current report Send target weight Set target weight Send all weights Send a statistics summary Send serial number Turns on the each bird print Turns off the each bird print Turns on the histogram print Turns off histogram print Turns on statistic print Turns off the statistic print Send bird dump in binary Data Pod format Send the date ddmmyy Send the time hhmm Set the date...

Open the catalog to page 9
BW-2050 Full Kit - 10

INDEX The BW-2050 is a rugged unit designed for outdoor use but it should be handled with care. The unit can be cleaned with a damp cloth but under no circumstances be immersed in water. Carrying the unit by the hook may cause damage to the loadcell and stop you from weighing. This unit is fitted with rechargeable batteries and will last for 3-4 years. Subject Page

Open the catalog to page 10
BW-2050 Full Kit - 11

Weltech Interna onal Limited Weltech Interna onal Limited manufacture the BW‐2050 to the highest specifica on and our aim is to con nue to improve its opera on and reliability and give our customers a product that suits their requirements. SERVICE. For service and repairs contact your local agent. Weltech Interna onal Limited 10 Bramley Road St.Ives Cambridgeshire PE27 3WS Email : Tel : Fax :

Open the catalog to page 11