Pressure transmitter For general industrial applications WIKA data sheet PE 81.60 For further approvals, see Page 10 Pressure transmitter, model A-10 Applications■ Machine building ■ Measurement and control technology ■ Excellent quality and proven technology ■ Exceptionally large variety covers almost all applications ■ All configurable variants are available at short notice from quantities of 1 upwards The field-proven model A-10 pressure transmitter (pressure sensor) is the all-rounder for pressure measurement in industrial environments. Compactly built, it can be integrated into a wide range of machine designs. The many measuring ranges, and special measuring ranges, contribute to its universal applicability. Our many years of experience and precise knowledge of customer needs have been incorporated into the development of the model A-10. It has been proving itself in countless applications for over ten years. The consistently high quality and its reliable function are appreciated worldwide and regularly confirmed by both internal and external audits. This bestseller can tolerate up to 100 million load cycles with almost constant precision. Depending on the requirement, the model A-10 measures gauge pressure, vacuum and absolute pressure. It can be WIKA data sheet PE 81.60 • 06/2025 flexibly configured into over 2 million variants and can thus be effortlessly integrated into almost any plant concept. Every custom-configured model A-10 will be ready for shipment, starting from a batch size of 1, no later than five working days after the order is placed. Large quantities can also be delivered quickly. The short delivery times help both OEMs to meet short production times and distributors to procure the right product for their customers quickly. The model A-10 is particularly cost-efficient and offers very good performance, matched to the majority of applications in terms of precision and robustness. The high reliability and long service life ensure low maintenance and replacement costs. Data sheets showing similar products: Pressure transmitter for demanding industrial applications; model S-20; see data sheet PE 81.61 Pressure sensor with IO-Link; model A-1200; see data sheet PE 81.90
Open the catalog to page 1WIKA data sheet PE 81.60
Open the catalog to page 2WIKA data sheet PE 81.60 • 06/2025
Open the catalog to page 3WIKA data sheet PE 81.60 • 06/2025
Open the catalog to page 4WIKA data sheet PE 81.60
Open the catalog to page 5Output signal WIKA data sheet PE 81.60 • 06/2025
Open the catalog to page 61) Not possible with non-linearity 0.25 % BFSL. 2) Only possible for temperatures to 80 °C [176 °F]. 3) Not possible with measuring ranges < 0.1 bar [< 1.45 psi] (or equivalent). 4) < 300 ms with DNV approval and measuring range 2 0.4 bar [2 5.8 psi] ... < 0.6 bar [< 8.7 psi]. Other output signals on request. Electrical connection 1) The stated IP codes only apply when plugged in using mating connectors that have the appropriate IP code. 2) Not feasible with cULus approval. 3) Not feasible with DNV approval. Further details on: electrical connection WIKA data sheet PE 81.60 • 06/2025
Open the catalog to page 7Cable outlet, unshielded Cable outlet, OEM version, unshielded U+ Positive power supply terminal U- Negative power supply terminal S+ Analogue output WIKA data sheet PE 81.60 • 06/2025
Open the catalog to page 8Operating conditions Ambient temperature limit 2) 5) Medium temperature limit Storage temperature limit Voltage signal, current signal and ratiometric Extended temperature ranges 1) Voltage signal Current signal 1) For restrictions of the temperature ranges due to the seal used, see “Further details on: process connection”. 2) Restrictions and derating of the ambient temperature depend on the medium temperature. 3) With cULus approval the minimum ambient and medium temperature is -30 °C [-22 °F]. 4) Only with auxiliary power DC 8 ... 30 V. 5) Only with housed mounting location that is protected...
Open the catalog to page 9Certificate 2.2 test report per EN 10204 (e.g. state-of-the-art manufacturing, material proof, indication accuracy) WIKA data sheet PE 81.60 • 06/2025
Open the catalog to page 10With circular connector M12 x 1 Ml 2x1 With standard cable outlet, unshielded With cable outlet, OEM version, unshielded WIKA data sheet PE 81.60 • 06/2025
Open the catalog to page 11Process connections Flange connection → For further process connections, see technical information IN 00.14. WIKA data sheet PE 81.60 ∙ 06/2025
Open the catalog to page 12Mating connector Seal for mating connector 1) Connector not permissible for model A-10 with DNV approval. WIKA data sheet PE 81.60 • 06/2025
Open the catalog to page 13Ordering information Model / Non-linearity / Measuring range / Process connection / Seal / Permissible medium temperature range / Output signal / Auxiliary power / Electrical connection / Certificates / Approvals Standard article © 2011 WIKA Alexander Wiegand SE & Co. KG, all rights reserved. The specifications given in this document represent the state of engineering at the time of publishing. We reserve the right to make modifications to the specifications and materials. In case of a different interpretation of the translated and the English data sheet, the English wording shall prevail. WIKA...
Open the catalog to page 14