Blockpumps Vogel Series LSB WITH HYDRAULICS ACCORDING TO ISO 2858
Open the catalog to page 1Technical Data Performance: m m m Capacity up to Head up to Speed up to 16bar (235psig) Pump sizes 50-32-315, 65-40-315, 80-50-315 up to 25bar (363psig) Volute casing pumps for higher capacities, pump sizes up to DN 600 (24’’) and capacities up to 4600m3/h (20250 USgpm) refer to design LS. Model LSB is a horizontal block pump based on hydraulics according to ISO 2858 / EN 22858 (from model LSN) with close coupled TEFC motor according to IEC design B 5. Standard IEC TEFC electric motors, design B 5 power range 2950rpm up to 37kW and 1450rpm up to 30kW protection IP 55, insulation class...
Open the catalog to page 2Cyclone Seal Chamber m The patented design of the cyclone seal chamber improves the life time of the mechanical seal. Spiral grooves in the big conical seal chamber avoid contamination of sealing environment by solids. Enlarged clearance and big volume improve cooling and lubrication of the mechanical seal. The self venting design prevents the accummulation of gas (vapor) in the sealing environment. Seal chamber installation dimensions in accordance with ISO 3096 / EN 12756 he correct seal selection is essential for the life time of the mechanical T seal. The flexible sealing system...
Open the catalog to page 4Simplyfies installation, lower installation costs. No alignment of pump unit required. Stub shaft made of Duplex (1.4462) and motor adapters for standard IEC motors design B 5. Dimensions of block version reduced by 30% compared with frame mounted pumps. Ideal for OEMs or installation under space limited site conditions. Standard IEC TEFC motors Voltage / Frequency Insulation class F (temperature according to B) Standard motors for operation with frequency inverters and HYDROVAR.
Open the catalog to page 5Heavy Duty Casing Casted heavy duty, foot supported design provides maximum resistance against pipe loads Minimum 3mm corrosion allowance maximizes pump life Standard 3/8”-NPT casing drain for safe and simple maintenance ISO 2858 dimensions for easy installation in all systems and interchangeability Impeller Precision cast, enclosed impeller design for maximum performance and low NPSH Back vanes or balance holes reduce axial thrust and seal pressures for extended seal and motor life Key driven to secure maximum reliability Optional wear rings renew pump performance and extend pump life...
Open the catalog to page 6Standard design with improved reliability Motor Adapter Precision machined fits maintain alignment between pump end and motor eliminating costly pre-alignment during installation Couplings and baseplates are not required, thus reducing capital costs Compact, space saving arrangement ideal for OEMs or space constrained installations Motor connection for standard IEC (B5) motors Stub Shaft Stub shaft directly mounted on motor shaft, rigid one piece design for optimized radial run out Standard Duplex SS (1.4462) construction for maximum corrosion resistance Engineered Seal Chamber Patented...
Open the catalog to page 7Part and Material List 400 161 Item Number Part Name Seal Chamber Stub Shaft Ductile Iron Ductile Iron Motor Lantern Cast Iron Casing Gasket Non-Asbestos Aramid Fiber Fixing Ring Casing Drain Plug Cast Material Specifications Equivalent Materials Cast material Cast Iron Ductile Iron Stainless Steel
Open the catalog to page 8LSB and HYDROVAR Pumping System Solutions By optimizing the pump performance according to system demand high potential of savings are achievable. Energy savings up to 70 %. m Increasing reliability and improved life time due to con- trolled operating conditions avoid dry run, head losses and cavitation. m Reduced hydraulic forces improve bearing and mechanical seal life time. m Lower installation costs due to elimination of control valves as well as panels and controllers. m Patented microprocessor based pump controller for variable speed operation, specifically developed for pump...
Open the catalog to page 9Controller Mode „Normal” Control for difference pressure Control for flow Flowmeter At controller mode „normal” the operating frequency increases in case of decreasing signal measuring. Controller Mode „Invers” Control for difference pressure At controller mode „invers” the operating frequency decreases in case of decreasing signal measuring. For more detailed information of HYDROVAR refer to se
Open the catalog to page 10Program Extension Volute Casing Pumps LSN m Frame mounted pumps according to ISO 2858 and ISO 5199 Refer to separate brochure Volute Casing Pumps - Design LS m Extended performance range to model LSN, pump sizes up to DN 600 (24“) Refer to separate brochure Förderstrom - Débit Förderhöhe [m] - Total head [ft] - Hauteur de refoulement [m] Förderhöhe [m] - Total head [ft] - Hauteur de refoulement [m]
Open the catalog to page 11Xylem 1) The tissue in plants that brings water upward from the roots; 2) a leading global water technology company. We’re 12,500 people unified in a common purpose: creating innovative solutions to meet our world’s water needs. Developing new technologies that will improve the way water is used, conserved, and re-used in the future is central to our work. We move, treat, analyze, and return water to the environment, and we help people use water efficiently, in their homes, buildings, factories and farms. In more than 150 countries, we have strom, long-standing relationships with customers...
Open the catalog to page 12All Xylem Water Solutions Herford GmbH (Wedeco) catalogs and technical brochures
-